Nd Acceleration Frequency; Parameter Setting Tables - Hitachi SJ300-EL Series Instruction Manual Supplement

Inverter for elevator applications three-phase input 200v class; three-phase input 400v class
Hide thumbs Also See for SJ300-EL Series:
Table of Contents

Advertisement

3. Parameter Setting Tables

Function Mode
Code
Function name
A001
Frequency setting selection
A002
Operation setting selection
A003
Base frequency
A004
Maximum frequency
A005
[AT] Selection
A006
[O2] Selection
*A011
0 start
*A012
0 end
A013
0 start rate
A014
0 end rate
A015
0 start selection
A016
O, OI, O2 sampling
A019
Multi-speed selection
*A020
Multi-speed 0
Acceleration time for multi-speed 0
F002
and 7
Deceleration time for multi-speed 0
F003
and 7
*A021
Multi-speed 1
A221
Acceleration time for multi-speed 1
A321
Deceleration time for multi-speed 1
A022
Multi-speed 2
A222
Acceleration time for multi-speed 2
A322
Deceleration time for multi-speed 2
*A023
Multi-speed 3
A223
Acceleration time for multi-speed 3
A323
Deceleration time for multi-speed 3
*A024
Multi-speed 4
A224
Acceleration time for multi-speed 4
A324
Deceleration time for multi-speed 4
*A025
Multi-speed 5
A225
Acceleration time for multi-speed 5
A325
Deceleration time for multi-speed 5
*A026
Multi-speed 6
A226
Acceleration time for multi-speed 6
A326
deceleration time for multi-speed 6
*A027
Multi-speed7 (creep speed)
A227
Acceleration time for multi-speed 7
A327
deceleration time for multi-speed 7
A042
Manual torque boost
A043
Manual torque boost point
st
A044
1
control
nd
A244
2
control
A045
Output voltage gain
A051
DC braking selection
A052
DC braking frequency
A053
DC braking wait time
A054
DC braking power
A055
DC braking time
A056
DC braking edge/level selection
A057
DC braking power (starting time)
A058
DC braking time(starting time)
A059
DC braking carrier frequency
st
*A061
1
frequency maximum limiter
st
*A062
1
frequency minimum limiter
*A063
Jump frequency1
*A064
Jump frequency Width 1
*A065
Jump frequency2
*A066
Jump frequency Width 2
*A067
Jump frequency3
*A068
Jump frequency Width 3
*A069
Acceleration stop frequency
A070
Acceleration stop time
A071
Selection of Torque Bias Input
*A074
Frequency Conversion Enable
*A075
Linear Speed at Max Freq (A004)
A081
AVR selection
A082
Motor voltage selection
Chapter 3 – Parameter Setting Tables
00(VR)/01(terminal)/02(operator)/03(RS485)/04(option1)/05(option2)
01(terminal)/02(operator)/03(RS485)/04(option1)/05(option2)
30. - Maximum. frequency(Hz)
00: Select between [O] and [OI] at [AT]/ 01: Select between [O] and [O2] at [AT]
00: No summing [OI] and [O2]/01: Sum [OI] and [O2], no negative/02: Sum [OI] and [O2] negative allowed
0.00-99.99/100.0-400.0 (Hz)
0.00-99.99/100.0-400.0 (Hz)
00 (external starting frequency)/01(0Hz)
00(binary : range is to 16 stage speed with 4 terminals)/
01(bit : range is to 8 stage speed with 7 terminals)
0.00, starting frequency-maximum. frequency(Hz)
0.01-99.99/100.0-999.9/1000.-3600.(s)
0.01-99.99/100.0-999.9/1000.-3600.(s)
0.00, starting frequency-maximum. frequency(Hz)
0.01-99.99/100.0-999.9/1000.-3600.(s)
0.01-99.99/100.0-999.9/1000.-3600.(s)
0.00, starting frequency-maximum. frequency(Hz)
0.01-99.99/100.0-999.9/1000.-3600.(s)
0.01-99.99/100.0-999.9/1000.-3600.(s)
0.00, starting frequency-maximum. frequency(Hz)
0.01-99.99/100.0-999.9/1000.-3600.(s)
0.01-99.99/100.0-999.9/1000.-3600.(s)
0.00, starting frequency-maximum. frequency(Hz)
0.01-99.99/100.0-999.9/1000.-3600.(s)
0.01-99.99/100.0-999.9/1000.-3600.(s)
0.00, starting frequency-maximum. frequency(Hz)
0.01-99.99/100.0-999.9/1000.-3600.(s)
0.01-99.99/100.0-999.9/1000.-3600.(s)
0.00, starting frequency-maximum. frequency(Hz)
0.01-99.99/100.0-999.9/1000.-3600.(s)
0.01-99.99/100.0-999.9/1000.-3600.(s)
0.00, starting frequency-maximum. frequency(Hz)
0.01-99.99/100.0-999.9/1000.-3600.(s)
0.01-99.99/100.0-999.9/1000.-3600.(s)
00/(VC)/01(VP1.7power)/02(free V/f setting)/03(SLV)/
00/(VC)/01(VP1.7power)/02(free V/f setting) /03(SLV)/04(0Hz-SLV)
00(edge action)/01(level action)
st
0.00, 1
frequency lower limiter-maximum frequency(Hz)
0.00, start frequency- 1
0.00-99.99/100.0-400.0(Hz)
0.00-99.99/100.0-400.0(Hz)
0.00-99.99/100.0-400.0(Hz)
0.00-99.99/100.0-400.0(Hz)
00: [O] input/01: [OI] input/02: [O2] input
00(ON always)/01(OFF always)/02(OFF on decelerating)
200/215/220/230/240, 380/400/415/440/460/480
25
Setting range
30. - 400. (Hz)
0.-100.0(%)
0.-100.0(%)
1.-30.(times)
0.0-20.0(%)
0.0-50.0(%)
04(0Hz-SLV)/05(V2)
20. - 100.
00(invalid)/01(valid)
0.00-60.00(Hz)
0.0 - 5.0(s)
0. - 100. (%)
0.0 - 60.0(s)
0. - 100. (%)
0.00-60.0(s)
0.5-15(kHz) Derating
st
frequency maximum limiter (Hz)
0.00-10.00(Hz)
0.00-10.00(Hz)
0.00-10.00(Hz)
0.00-60.0(s)
00 (OFF) / 01 (ON)
0.1-3000.0
Initial data
02
01
60.
60.
0.00
0.00
0.
100.
01
8.
00
0.00
30.0
30.0
50.00
5.0
5.0
40.00
5.0
5.0
20.00
5.0
5.0
10.00
5.0
5.0
10.00
5.0
5.0
10.00
5.0
5.0
2.00
5.0
5.0
1.0
5.0
05
00
90.
00
0.50
0.0
0.
0.0
01
0.
0.0
5.0
0.00
0.00
0.00
0.50
0.00
0.50
0.00
0.50
0.00
0.0
00
00
100.0
00
(200/400)

Advertisement

Table of Contents
loading