Hitachi SJ100DN DeviceNet Series Addendum Instruction Manual Addendum page 87

Sj100dn devicenet series
Hide thumbs Also See for SJ100DN DeviceNet Series Addendum:
Table of Contents

Advertisement

Intelligent Terminal Functions
"C" Group Parameters
Func.
Name
Code
C_01 Terminal [1] function
C_02 Terminal [2] function
C_03 Terminal [3] function
C_11 Terminal [1] active state
C_12 Terminal [2] active state
C_13 Terminal [3] active state
C_21 Terminal [11] function
C_22 Terminal [12] function
C_31 Terminal [11] active state
C_32 Terminal [12] active state
C_41 Overload level setting
C_42 Frequency arrival setting for
accel
C_43 Arrival frequency setting for
decel
Supported Services, DeviceNet Class ID = 105
Service Name
Get_Attribute_Single
Set_Attribute_Single
DeviceNet Class ID = 105
Inst Attr Size
1
101
1
1
102
1
1
103
1
1
111
1
1
112
1
1
113
1
1
121
1
1
122
1
1
131
1
1
132
1
1
141
2
1
142
2
1
143
2
Code
0Eh
10h
SJ100DN Inverter
Range
Scaling
0, 1, 2, 3, 4, 5, 6, 7,
8, 9, 11, 12, 13,
15, 18, 19, 20, 21,
22, 25, 27, 28, 31
(see manual,
Chapter 3)
(same as above)
(same as above)
0 normally open
1 normally closed
0 normally open
1 normally closed
0 normally open
1 normally closed
0, 1, 2, 3, 5 (see
manual, Ch. 3)
(same as above)
0 normally open
1 normally closed
0 normally open
1 normally closed
0% to 200% rated
100
current, in A
0.0 – 360.0Hz
100
0.0 – 360.0Hz
100
Description
87
Get/
Set
G/S
G/S
G/S
G/S
G/S
G/S
G/S
G/S
G/S
G/S
G/S
G/S
G/S

Advertisement

Table of Contents
loading