"P" Group: DeviceNet Network Settings
The following table describes the DeviceNet network settings for SJ100DN inverters.
"P" Function
Func.
Name
Code
P_41 DeviceNet baud rate
P_42 DeviceNet MAC ID
P_43 DeviceNet control
enable
P_44 DeviceNet comm
watchdog timer
P_45 Inverter action on
DeviceNet comm error
P_46 DeviceNet polled I/O:
Output instance number
P_47 DeviceNet polled I/O:
Input instance number
P_48 Inverter action on
DeviceNet idle mode
P_49 DeviceNet motor poles
setting for RPM
Note 1:
Functions P_46 and P_47 must be set as a corresponding pair. Valid settings
for P_46 / P_47 are 20 / 70, 21 / 71, or 100 / 101 (default). Other setting
combinations can cause a DeviceNet network error.
Description
Three options; select codes:
00... 125 kbps
01... 250 kbps
02... 500 kbps
Selects the DeviceNet node
address, range is 0 to 63
Two options; select codes:
00... Disable
01... Enable
Range is 0.00 to 99.99 seconds
Five options:
00... Trip
01... Decelerate and trip
02... Hold last speed
03... Free-run stop
04... Decelerate and stop
Three settings:
20, 21, 100 *1
Three settings:
70, 71, 101 *1
Five options:
00... Trip
01... Decelerate and trip
02... Hold last speed
03... Free-run stop
04... Decelerate and stop
Range is 00 to 38 (even
numbers only), two types:
00... For freq. setting (Hz)
02 to 38... For speed (RPM)