Removing The Cr Motor/Pulley Assembly - Epson Stylus Pro 9000 Service Manual

B0 wide-format professional inkjet printer
Hide thumbs Also See for Stylus Pro 9000:
Table of Contents

Advertisement

EPSON Stylus Pro 9000

REMOVING THE CR MOTOR/PULLEY ASSEMBLY

1. Remove the L/R Side Covers as described in "L/R Side Covers Removal"
on page 75.
2. Manually release the Carriage Lock and move the carriage away from the
capping position.
3. On the Left Side Frame, find the CR Driven Pulley and loosen the two
screws securing it to the frame. Then loosen the tension on the steel belt.
Loosen these two
Figure 4-23. CR Motor Removal & CR Steel Belt Loosening
When removing the CR Motor, the following adjustment
procedures are required.
n
CR Steel Belt Tension Adjustment
Disassembly & Assembly
CR Driven
Disassembly Flow
4. Towards the right side of the frame there is one screw securing the steel
belt, remove this screw. Then remove one edge of the steel belt, and finally
pull out the steel belt to the Right Side Frame.
Remove one Hex
Figure 4-24. CR Motor Removal/Steel Belt Removal
5. Loosen the Hex (Allen key) screw (2.5mm), and then remove the bearing
stopper attached to end of the CR Motor Shaft.
Revision B
CR Steel Belt
88

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents