DFX-8500
3.2.6.2 Ribbon Feed Change Lever Unit Removal
Step 1: Release the three hooks securing the ribbon feed gear cover to the ribbon feed motor frame and
remove the cover and the ribbon feed gear.
Step 2: Disconnect the three connectors for the ribbon feed motor, tractor select sensor, and the ribbon
jam sensor from the connector junction board, as shown in Figure 3-47 and Figure 3-48.
Step 3: Remove the head damper from the left side frame.
Step 4: Remove the fan on the left frame. (Refer to Section 3.2.6.1.)
Figure 3-46. Ribbon Feed Change Lever Unit Removal (1/2)
Step 5: Remove the two CBS (M3x6) screw securing the ribbon feed change lever unit to the left side frame,
then remove the ribbon feed change lever unit.
Figure 3-47. Ribbon Feed Change Lever Unit Removal (2/2)
3-32