17.2 Setting parameter values with the V810 control panel
Changing technician-level parameter values
Entering the technician-level code number
Turn off the main switch.
All plugs must be plugged in to the sewing-drive control.
Press and hold down the "P" key.
Turn on the main switch. "C-0000" appears in the display.
Release the "P" key.
Enter code no. 1907. Press the "+" or "-" keys to alter the value of
the flashing digit. Press the ">>" key to move to the next digit.
Press the "E" key. The first technician-level parameter F-100 is
displayed.
Selecting parameters and changing values
Press the "+" and "-" keys to select the next or preceding parameter.
The parameter can be entered direct with the ">>", "+"and "-" keys.
Press the "E" key. The value of the selected parameter is displayed.
Press the "+" and "-" keys to change the parameter value.
Press the "E" key to display the next parameter or the "P" key to
display the same parameter.
Saving changed parameter values
Press the "P" key to terminate programming.
Sew a complete seam, i.e. push the pedal forward and then fully
back. The change is saved.
If no seam is sewn, the change is lost.
Press the "P" key again to return to programming level.
Changing manufacturer-level parameter values
Entering the manufacturer-level code number
Turn off the main switch.
All plugs must be plugged in to the sewing-drive control.
Press and hold down the "P" key.
Turn on the main switch. "C-0000" appears in the display.
Release the "P" key.
Enter code no. 3112. Press the "+" or "-" keys to alter the value of
the flashing digit. Press the ">>" key to move to the next digit.
Press the "E" key. The first manufacturer-level parameter F-200 is
displayed.
Continue as for "Selecting parameters and changing values"