DURKOPP ADLER Kit 0367 595084 Instructions page 4

Instructions for converting for manual backtacking

Advertisement

Available languages

Available languages

Instructions for converting for manual backtacking
Remove two circlips 7 from the shaft 0367 166020.
Pull the shaft out.
Mount the included shaft and slip circlips on.
Tighten the pressure screws of the lever and the frame.
Make drillhole 6H13 according to drilling template 0367 165990 (with customary 6 mm steel drill).
2
Knock in pin 2 (part no. 0578 000868).
Knock pin 8 (part no. 0994 271360) in the
drillhole already existing and put the included
piece of hose 10 (part no. 0367 165980)
on the pin.
Put lever 3 (part no. 0367 165960) on shaft.
Hang in spring 4 (part no. 0667 165220).
Put clamping block 5 (part no. 0367 166003)
on shaft
With the maximum stitch length the pin 9 of
the clamping block 0367 166003 must abut on
lever 0367 165960.
Tighten screw 6 at the clamping block 5.
Fasten handle 13 on lever 3 with screws 14
(9204 201667).
Adjusting the stitch length: see service
instructions chapter 2.3
Adjusting the short tail trimmer
(only with cl. 0367-170315 and 0367-180315):
see service instructions chapter 2.9
Mount valve cover, included belt protection,
handwheel and synchronizer
.
Ausgabe/Edition:
01. 2006
Umbauanleitung für Handverriegelung
Teilesatz 0367 595084
Kit 0367 595084
Printed in Federal Republic of Germany
Teile-Nr./ Part-No.:
13 14
3
9
5
Blatt:
Sheet: 4
0791 367770
4
6
von
from 4

Advertisement

loading

This manual is also suitable for:

0367 595084