Dc Mode; Special Features Of Operation; Aes Mode - Dometic RM2607 Service Tips Manual

Ames/aes/royale/elite refrigerators
Table of Contents

Advertisement

DC MODE (3-Way Models Only)
When operating in the DC mode, the DC mode indicator lamp (A) will be illuminated. All other mode
lamps will be off. The DC mode overrides all other operating modes. If one of the other operating modes
is desired, the DC selector button (2) must be in the UP (OFF) position.

SPECIAL FEATURES OF OPERATION

This control system contains a feature where it will continue to operate the cooling system in the event
of a failure of a major operating component. Two different modes of operation can occur in this category.
If the display module becomes nonfunctional, the control system will revert to full automatic operation
selecting the best energy source available with AC, DC (3-way only) and GAS priority. The temperature
of the refrigerator will be maintained at the MID position within normal temperature tolerances. The
power module will continually attempt to reestablish operation of the display module.
The second Special Feature of operation will execute when a failure of the temperature sensing device or
associated electronic circuitry occurs. If this should occur, the control system will operate on the energy
source selected via the control panel. The cooling unit will run continuously on the selected energy
source. The refrigerator will continue to operate in this mode indefinitely or until a new sensor is installed
and the system is reset.
NOTE: The operational range of these refrigerators is 46
AES REFRIGERATOR OPERATION
Models Include: RM3607 and RM3607

AES MODE

The AES mode of operation takes priority over all other operating modes. If more than one mode selector
button (2), (3) or (4) is in the down position, the priority is from left to right.
When operating in the AES mode, the AES mode indicator lamp (A) will illuminate. In this mode the
control system will automatically select the energy source with AC having top priority, DC second priority
and GAS third priority. If the control system has selected a particular energy source such as AC, and then
it becomes unavailable, it will automatically seek out the next available energy source.
AC/GAS MODE
When operating in the AC/GAS mode the AC/GAS mode indicator lamp (B) will illuminate. In this mode of
operation the control system will automatically select between the AC and GAS energy sources with AC
having first priority.
o
to 35
3-WAY AES DISPLAY PANEL
o

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents