FLUE CAP (AMES/AES MODELS ONLY)
The flue cap is located at the top of the flue tube and is attached with a screw.

FLUE TUBE

The flue tube must be cleaned periodically, at least once a year
Clean by using a flue brush, Dometic Part No. 0151404001.
WIRING

EXTERNAL WIRING

1.120 Volts AC Connection

The refrigerator is equipped with a three-prong (grounded) plug for protection against shock hazards
and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove
the grounding prong from this plug.
2.12 Volt DC Connection
The refrigerator must be connected to the battery circuit with two wires of adequate capacity to avoid
voltage drop.
The wire gauge should be chosen in accordance with the Table shown below.
Do not use the body or chassis of the vehicle as a substitute for either of the two conductors. No other
electrical equipment or lighting should be connected to the refrigerator circuit.