Leveling - Dometic RM2607 Service Tips Manual

Ames/aes/royale/elite refrigerators
Table of Contents

Advertisement

2 9 3 2 6 7 6 0 0

LEVELING

The absorption design utilizes no mechanical pumps or compressors to circulate the refrigerant within the
system, so proper leveling must be maintained to provide the correct refrigerant flow. Without proper
leveling, refrigerant within the cooling unit will collect and stagnate at certain areas. Both Dometic and Servel
brand refrigerators have a type of cooling unit that utilizes an enclosed pump tube surrounded by a solution.
The vehicle needs to be leveled so it is comfortable to live in. When the vehicle is moving, leveling is not
critical as the rolling and pitching movement of the vehicle will pass to either side of level, keeping the
refrigerant from accumulating in the piping.
ROYALE & ELITE
TYPICAL 3-WAY
WIRING DIAGRAM
@-CIRCUIT
BOARD
DISPLAY
@CIRCUIT
BOARD
POWER
R T
A
H
BLOCK
T
O I N
25