Dometic RM2611 Installation & Operating Instructions Manual

Refrigerator for lp/gas and electric operation
Hide thumbs Also See for RM2611:

Advertisement

USA
SERVICE OFFICE
The Dometic Corp.
509 So. Poplar St.
LaGrange, IN 46761
CANADA
Dometic Dist.
866 Langs Dr.
Cambridge, Ontario
CANADA N3H 2N7
INSTALLATION &
OPERATING INSTRUCTIONS
Form No. 3105586.006 12/93
The Dometic Corp.
LaGrange, IN 46761
© 1993 The Dometic Corporation
FOR YOUR SAFETY
If you smell gas:
1. Shut off gas supply at
main valve.
2. Open windows.
3. Don't touch electrical
switches.
4. Extinguish any open flame.
5. Immediately call your gas
supplier.
FOR YOUR SAFETY
Do not store or use gasoline
or other flammable vapors
and liquids in the vicinity of
this or any other appliance.
INDEX
Installation ..............................
Operating Instructions ..........
Maint. & Service .................... 12
Wiring Diagram ...................... 14
RECORD THIS INFORMATION FOR FUTURE REFERENCE
BEFORE INSTALLING THE UNIT:
Model No. _______________
Date Purchased __________ Place of Purchase ______________
MODEL RM2611 AND RM2811
Automatic/Manual Energy Selector
REFRIGERATOR FOR LP/GAS
AND ELECTRIC OPERATION
Improper installation, adjustment,
alteration, service or maintenance
can cause injury or property dam-
age. Refer to this manual. For assis-
tance or additional information
consult a qualified installer, service
agency or the gas supplier.
Cet appareil doit être réparé
seulement par un réparateur
autorisé. Modification de l'appareil
pourrait être extrèmement
dangeruse, et pourrait causer mal
ou mort.
REFRIGERATOR
RM2611
RM2811
Page
2
8
IMPORTANT INSTRUCTIONS
1
_____________________ Serial No.
WARNING
AVIS
MODEL
READ CAREFULLY

Advertisement

Table of Contents
loading

Summary of Contents for Dometic RM2611

  • Page 1 RECORD THIS INFORMATION FOR FUTURE REFERENCE BEFORE INSTALLING THE UNIT: Model No. _______________ _____________________ Serial No. Date Purchased __________ Place of Purchase ______________ MODEL RM2611 AND RM2811 Automatic/Manual Energy Selector SERVICE OFFICE The Dometic Corp. REFRIGERATOR FOR LP/GAS 509 So. Poplar St.
  • Page 2: Section A. Installation

    SECTION A. INSTALLATION 1. GENERAL INSTRUCTIONS The lower side vent is fitted with a panel which provides an adequate access opening for ready serviceability of the This appliance is designed for storage of foods and burner and control manifold of the refrigerator. This should be storage of frozen foods and making ice.
  • Page 3: Ventilation Heights

    FIG. 3 Refrigerator Overall Installation Recess Model Dimensions Dimensions Dimensions Height Width Depth Height Width Depth Height Width Depth RM2611 (Inches) 22-23/32 24-9/16 49-7/32 21-17/32 23-19/32 49-17/32 21-13/16 24-3/32 (mm) 1295 1250 1258 RM2811 (Inches) 56-13/16 24-39/64 24-9/16 55-1/8 23-7/16...
  • Page 4: Gas Connection

    FIG. 5 INSTALLING REFRIGERATOR IN ENCLOSURE NOTE: DO NOT install the appliance directly on carpeting. Carpeting must be removed or protected by a metal or wood panel beneath the appliance, which extends at least the full width and depth of the appliance. INSTALLATION: The refrigerator must be installed in a substantial enclosure and must be level.
  • Page 5: Testing Lp Gas Safety Shutoff

    FIG. 6 Heater Rating Plate Flue Baffle Power Protection Module Cover Cover Evaporation Tray 12 V olt Manual G as Drip P an Terminal B lock Shutoff V alve Burner Jet Flexible C ord Inlet F itting 9. TESTING SAFETY SHUTOFF The gas safety shutoff must be tested after the refrigerator is connected to LP gas supply.
  • Page 6 TYPE MAX. MIN. MAX. MIN. The refrigerator is normally delivered without the door pan- RM2611 els. Before starting the mounting work, check that the panel upper dimensions are in compliance with those given in the Table inch 12-3/64 11-31/32 20-9/32 20-13/64 on this page and the instructions are read thoroughly.
  • Page 7 (See FIG. 9.) FIG. 9 SECTION B. CERTIFIED VENT SYSTEM KITS REFRIGERATOR MODEL COMPONENTS PART NO. RM2611 ROOF BASE 3103633.XXX * RM2811 ROOF COVER 3103634.XXX * LOWER SIDE VENT 3102277.XXX * POWER VENT POWER VENT ASM.
  • Page 8: Section C. Operating Instructions

    SECTION C. OPERATING INSTRUCTIONS 1. IMPORTANCE OF LEVELING A REFRIGERATOR In an absorption refrigerator system, ammonia is liquefied in Any time the vehicle is parked for several hours with the the finned condenser coil at the top of the refrigerator. The refrigerator operating, the vehicle should be leveled to liquid ammonia then flows into the evaporator (inside the prevent this loss of cooling.
  • Page 9: Auto Mode

    3. OPERATING INSTRUCTIONS CHECK indicator lamp is on, it will function properly, but the CHECK indicator lamp will not go off until the main 2-WAY MODEL power ON/OFF button is pressed to the OFF then ON A. A 12 volt DC supply must be available for the electronic position.
  • Page 10 3-WAY MODEL ON/OFF button (1) to the OFF and then ON position. A. A 12 volt DC supply must be available for the electronic If the control is switched to AC or DC operation while the control to function. CHECK indicator lamp is on, it will function properly but B.
  • Page 11: How To Use The Refrigerator

    the anticipated need for ice, but be sure to move the The second standby mode of operation will execute when a thermostat back to normal setting, usually about mid-setting failure of the temperature sensing device or associated when the ice is formed. Food in the lower compartment may electronic circuitry occurs.
  • Page 12: Section D. Maintenance & Service

    Refer to Section A, Item 1 to 12 of Installation Instructions . 2. PERIODIC MAINTENANCE To keep your Dometic refrigerator operating efficiently and safely, periodic inspection and cleaning of several compo- nents once or twice a year is recommended.
  • Page 13: Manual Shut-Off Valve

    cleaning in the following manner: trode. Check the electrode for proper location and Unplug the refrigerator power cord from the 120 volt gap. (See FIG. 12). AC outlet (see FIG. 6). ELECTRODE Disconnect or shut off the 12 volt power to the refrigerator.
  • Page 14: Troubleshooting

    F. FUSES E. Flue baffle not inserted properly in flue tube. The 2-way AMES models are equipped with 2 fuses, one for F. Improperly set thermostat. the refrigerator control system and one for the AC cartridge See Section C. Operating Instructions, Item 3. heater.

This manual is also suitable for:

Rm2811