Diagnostic Messages

Message
Meaning
No message
1) Spa temperature is unknown.
on display
2) Spa is in Economy or Sleep
mode.
3) Power has been cut off to the
spa.
BUF
Internal problem detected.
dr
Insufficient water detected in
heater. Spa will be shut down for
15 minutes.
dry
Insufficient water detected in
heater. Spa is shut down.
dY
(Displays on third occurrence of
dr message.)
Ec
Indicates heater is in Economy
Mode.
--F or --C
Temperature unknown
HL
A difference in readings between
temperature sensors has been
HFL
detected indicating a possible
water flow problem.
IC
Potential freeze condition de-
tected.
ICE
LF
Persistent low flow problems.
Heater is shut down, but other
spa functions continue to run
normally. Displays on the fifth
occurrence of the HL or HFL mes-
sage within 24 hours.
OH
Overheat protection. The spa has
shut down. One of the sensors
OHS
has detected that the spa water
is 110°F.
Inground Spas
LTR20121002, Rev. A
Action Required
1) After pump has been running for 2 minutes tempera-
ture will be displayed.
2) In Economy or Sleep mode, the pump may be off for
hours outside a filter cycle. If you wish to see the cur-
rent spa temperature, either switch to Standard mode
or turn Jets1 on for at least two minutes.
3) The control panel will be disabled until power re-
turns. Spa settings and time of day will be preserved for
30 days with a battery back-up.
Repair required. Contact your dealer or service organi-
zation.
Check water level in spa. Refill if necessary. Make sure
pumps are been primed and filter cartridges are clean.
Press any button to reset or wait 15 minutes and spa
will automatically reset. If message spa does not reset,
call your dealer or service organization.
Follow directions for dr message and press any button
to reset spa. Spa will not automatically reset when dry
or dY is displayed.
None.
After the pump has been running for two minutes, the
temperature will be displayed.
Make sure spa is filled to proper level and that pumps
are primed and filter cartridges are clean. If message
does not reset, call your dealer or service organization.
No action required. The pumps and the blower will au-
tomatically activate regardless of spa status.
Follow action required for HL or HFL message. Heating
capacity of the spa will not reset automatically. Press
any button to reset.
DO NOT ENTER THE WATER. Remove the spa cover and
allow water to cool. At 107°F, the spa should automati-
cally reset. If spa does not reset, shut off the power to
the spa and call your dealer or service organization.