G (E Pl Ph Fn [A1 N1L N1H]...[Ak Nkl Nkh] Fn = - Citizen CT-S300 Command Reference Manual

Line thermal printer
Hide thumbs Also See for CT-S300:
Table of Contents

Advertisement

fn = 5: Function 5 Setting Customized Value
GS (E pL pH fn [a1 n1L n1H]...[ak nkL nkH] fn = 5
[Code]
<1d>H<28>H<45>pL pH fn [a1 n1L n1H]...[ak nkL nkH]
[Range]
4
fn = 5
1
1
[Default]
Described in the processing table for "a".
[Outline]
• Sets the customized value set in "a" to (nL + nH
• a = 3: Sets paper width to the size specified by (nL + nH
• a = 5: Sets printing density to the level specified by (nL + nH
(pL + pH
256)
65535
a
3 a = 5, 6, 97, 116, 201, 202
(nL + nH
256)
65535
a
3
Selects paper width.
5
Selects printing density.
6
Selects printing speed.
97
Selects the number of divisions for conducting head.
116
Selects printing color.
201
Sets ACK output position (only parallel I/F).
202
Selects input buffer full Busy output/cancel timing (idle capacity).
(nL + nH
256)
2
3*
6 (Default)
* No function with CT-S300.
(nL + nH
256)
65530
65531
65532
65533
65534
65535
0 (Default)
1
2
3
4
5
6
7
8
Function
Paper Width
58 mm
60 mm
80 mm
Printing Density
0.7 times
0.75 times
0.8 times
0.85 times
0.9 times
0.95 times
1.05 times
1.1 times
1.25 times
1.2 times
1.25 times
1.3 times
1.35 times
1.40 times
— 96 —
256).
256).
256).
1