Word Clock Out
The word clock output can follow the current sample rate up to 192 kHz (Follow Sample Rate),
or stay in the Single Speed range (Always Single Speed). The latter is default. These options
can only be changed by MIDI Remote, they can not be set directly at the unit.
Note: A reliable sample-accurate synchronicity between multiple devices having digital inter-
faces in S/MUX technology (ADAT and MADI) at sample rates in the Double Speed and Quad
Speed range is only possible when all units are synced by Single Speed word clock. Because of
the S/MUX method the device else can not know which of the incoming 2 (DS) or 4 (QS) word
clock edges is the right one.
8.7 Meter
METER PH provides a Peak Hold function for all level meters, either
permanently (ON) or switched off by Auto Reset (AR) after 3 seconds.
In mode ON, a reset (erasing the current peak values) is issued by a
single push of the PH button. The function itself is not changed.
8.8 Remote
REMOTE defines the source of MIDI remote control commands. Choices
are the MIDI DIN jack and the MADI input.
Note: Via MIDI remote control, all front panel controls can be locked
(Lock Keys). An exception is the LOCK KEYS key itself. Therefore a
locking of all the controls can be revoked directly at the unit at any time.
8.9 Lock Keys
LOCK KEYS deactivates all keys. This way the M-32 DA is secured
against accidental operating errors.
User's Guide M-32 DA © RME
17