START- -UP AND OPERATION

Checking Air Purifier Operation
WARNING
!
ELECTRICAL
SHOCK
HAZARD
Failure to follow this warning could result in personal injury
or death.
Before installing or servicing system, always turn off main
power to system. There may be more than one (1) disconnect
switch.
a. Attach the Perfect Air Air Purifier door to the cabinet. A mag-
net in the door (see Fig. 12) is used to activate a safety switch
in the power supply when the door is installed. The power
supply will not energize the air purifier unless the safety
switch is activated.
Door Switch Magnet
Fig. 12 - - Door Switch Magnet
b. Turn the HVAC system power on and adjust the thermostat or
Perfect Air System Control to activate the system fan.
c. Turn the Perfect Air Air Purifier power switch to on position.
d. The power indicator light above the Air Purifier power switch
should illuminate (see Fig. 13).
Power Indicator
Fig. 13 - - Power Indicator
e. Check to ensure the light goes off when the Perfect Air Air
Purifier power switch is set to off, when the blower goes off,
or when the HVAC system power is turned off.
NOTE: Upon power- -up, the light will come on for approximately
5 seconds and if no flow is detected, it will go off. If no air purifier
cartridge is detected, the flow sensor will detect this and turn off
after approximately 7 seconds.
Perfect Air Control
a. When the Perfect Air Air Purifier is used with an Perfect Air
Control, the Perfect Air Control can be configured to remind
the homeowner when it is time to change the Perfect Air Air
AND
HIGH
VOLTAGE
A06369
A06370
Purifier cartridge. This maintenance reminder can be based on
either the TrueSenset dirty filter algorithm or time. The in-
staller should use their discretion to select the most appropriate
option based on the initial system static pressure.
Maximizing Performance
a. Maximum air purification performance is obtained when the
furnace blower is set for continuous operation on the thermo-
stat or Perfect Air Control.

MAINTENANCE

The Perfect Air Air Purifier is designed to require minimal
maintenance. Maintenance is limited to the replacement of the air
purification cartridge and inspection/brush cleaning of the
ionization array. Frequency of air purifier cartridge replacement
and cleaning of the ionization array may vary depending on
ductwork design and local environmental conditions.
To replace the air purifier cartridge, complete the
following steps:
Step 5 — Turn the heating and cooling system power off.
WARNING
!
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal
injury or death.
Before installing or servicing system, always turn off main
power to system. There may be more than 1 disconnect
switch.
Step 6 — Turn the Perfect Air Air Purifier switch to the off
position.
Step 7 — Remove the Perfect Air Air Purifier door.
Step 8 — Slide out the old air purifier cartridge and discard.
Step 9 — Install the new air purifier cartridge.
NOTE: Make sure that the arrows on the air purifier cartridge
point toward the fan coil. This should be in the same direction as
airflow.
Step 10 — Replace the Perfect Air Air Purifier door.
Step 11 — Turn the Perfect Air Air Purifier switch to the on
position.
Step 12 — Turn heating and cooling system power on.
At the time of air purifier cartridge replacement, if a
powdery residue is noticed on the tips of the points in
the ionization array, proceed to clean them by
completing the following steps:
Step 1 — Turn heating and cooling system power off.
WARNING
!
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal
injury or death.
Before installing or servicing system, always turn off main
power to system. There may be more than 1 disconnect
switch.
Step 2 — Turn the Perfect Air Air Purifier switch to the off
position.
Step 3 — Remove the Perfect Air Air Purifier door.
Step 4 — Unplug the power cord and flow sensor cable (if
connected) from the enhancement module 9 (See Fig. 7 and 8)