INTRODUCTION

Congratulations for selecting the Perfect Airt Purifier for your
home comfort system! The Perfect Airt Purifier is proven to
remove and kill airborne germs and allergens, including viruses,
bacteria, and mold spores. The Perfect Airt Purifier is a
cornerstone of Bryant's Perfect AirtSolutions for providing
healthier, cleaner air in your home.

HOW IT WORKS

The Perfect Airt Purifier provides extremely high filtration
performance while killing captured contaminants, including
viruses, bacteria, and mold spores. The Perfect Airt Purifier
treats the entire air- -stream through a state of the art, three- -stage
process, exclusive to Bryant.
In stage one, the particles are electrically charged by a
precision- -point ionization array as they enter the Perfect Airt
Purifier.
In stage two, the charged particles are electrically attracted to
the air purification cartridge, which is located within an electric
field.
In stage three, captured particles are killed by electrical current
flow and ion bombardment.
Installation, Start- -Up, and
Operating Instructions
Page
. . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . .
3- -5
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
1
1
1
2
6
6
7
8
9

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service,
maintenance, or use can cause explosion, fire, electrical shock
or other conditions which may cause personal injury or property
damage. Consult a qualified installer, service agency, or your
distributor or branch for information or assistance. The
qualified installer or agency must use factory authorized kits or
accessories when modifying this product. Refer to the
individual instructions packaged with the kits or accessories
when installing.
Follow all safety codes. Wear safety glasses and work gloves.
Have fire extinguisher available. Read these instructions
thoroughly and follow all warning or cautions attached to the
unit. Consult local building codes and National Electrical Code
(NEC) for special requirements.
It is important to recognize safety information. This is the
safety- -alert symbol
and in instructions or manuals, be alert to the potential for
personal injury. Understand the signal words DANGER,
WARNING, and CAUTION. These words are used with the
safety- -alert symbol. DANGER identifies the most serious
hazards which will result in severe personal injury or death.
WARNING signifies hazards which could result in personal
injury or death. CAUTION is used to identify unsafe practices
which may result in personal injury or product and property
damage. NOTE is used to highlight suggestions which will
result in enhanced installation, reliability, or operation.
1
Fig. 1 - - GAPA Unit
. When you see this symbol on the unit
A06054

Advertisement

Table of Contents
loading

Summary of Contents for Bryant AIRT PURIFIER

  • Page 1: Table Of Contents

    ........INTRODUCTION Congratulations for selecting the Perfect Airt Purifier for your home comfort system! The Perfect Airt Purifier is proven to remove and kill airborne germs and allergens, including viruses, bacteria, and mold spores. The Perfect Airt Purifier is a cornerstone of Bryant’s Perfect AirtSolutions for providing...
  • Page 2: Application Considerations

    APPLICATION CONSIDERATIONS The Perfect Airt Purifier is designed for use in the return air duct of a forced air heating, cooling, and ventilation system. Models GAPAAXBB1625 and GAPAAXBB2025 are specifically designed for use in systems with a forced air gas furnace.
  • Page 3: Installation

    The Perfect Airt Purifier can be rotated 180 degrees to accommodate the cabinet orientation. c. The location of the Perfect Airt Purifier should be readily accessible. Enough room should be provided for periodic replacement of the air purifier cartridges.
  • Page 4 Seal seams with tape or caulking after the Perfect Airt Purifier cabinet has been secured. Furnace Adapters (x2) Return Duct Adapters (x4) Bottom Mount Fig. 4 - - Mounting Perfect Airt Purifier Cabinet CAUTION Side Mount A06029...
  • Page 5 EAC- -1 and EAC- -2 spade connections. Attach the ground ring to furnace chassis ground. A05274 NOTE: The Perfect Airt Purifier is to be powered by 115v/60 NOTE: The Perfect Airt Purifier should only be powered when airflow is present. The furnace control EAC spade connections provide power only when the furnace blower is operating.
  • Page 6: Start- -Up And Operation

    There may be more than one (1) disconnect switch. a. Attach the Perfect Airt Purifier door to the cabinet. A magnet in the door (see Fig. 9) is used to activate a safe- ty switch in the power supply when the door is installed.
  • Page 7: Troubleshooting

    The power supply will not energize the air purifier unless the safety switch is activated. Step 2—Check that the Perfect Airt Purifier power switch is in the on (closed) position. Step 3—Confirm that the furnace blower is operating.
  • Page 8: Specifications And Dimensions

    Specifications Color Cabinet Material Electrical Maximum Airflow (CFM) Efficiency Replacement Cartridge Dimensions 1 15/16 Specifications and Dimensions GAPAAXBB1625 Taupe Metallic 20 Ga. Powder Coated Steel 115v/60 Hz (from furnace EAC terminals) 1600 Equivalent to MERV 15 GAPBBCAR1625 GAPAAXBB1625 18---3/8 15---1/8 11---1/8 17---1/2 22--1/8...
  • Page 9: Warranty

    LIMITED WARRANTY FIVE-YEAR LIMITED WARRANTY –Bryant Heating and Cooling Systems (hereinafter referred to as “Company”) warrants this product to be free from defects in material and workmanship. If a defect is found within five years from date of original installation of product (whether or not actual use begins on that date) Company will provide a new or remanufactured part, at Company’s sole option, to replace any defective part, without charge for the part...
  • Page 10 Catalog No. II GAPA--- 0--- 2 EBryant Heating & Cooling Systems 7310 W. Morris St. Indianapolis, IN 46231 Printed in China Edition Date: 3/06 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Replaces: II GAPA---0---1...

This manual is also suitable for:

Gapaaxbb1625Gapaaxbb2025

Table of Contents