START- -UP AND OPERATION

Step 1—Checking Air Purifier Operation
WARNING
!
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal
injury or death.
Before installing or servicing system, always turn off
main power to system. There may be more than one (1)
disconnect switch.
a. Attach the Perfect Airt Purifier door to the cabinet. A
magnet in the door (see Fig. 9) is used to activate a safe-
ty switch in the power supply when the door is installed.
The power supply will not energize the air purifier un-
less the safety switch is activated.
b. Turn the HVAC system power on and adjust the
thermostat or Evolutiont System Control to activate
the system fan.
c. Turn the Perfect Airt Purifier power switch to on
position.
d. The power indicator light above the Air Purifier power
switch should illuminiate (see Fig. 8).
e. Check to ensure the light goes off when the Perfect
Airt Purifier power switch is set to off, when the
blower goes off, or when the HVAC system power is
turned off.
Step 2—Evolutiont Control
a. When the Perfect Airt Purifier is used with an
Evolutiont Control, the Evolutiont Control can be
configured to remind the homeowner when it is time to
change the Perfect Airt Purifier cartridge. This
maintenance reminder can be based on either the
TrueSenset dirty filter algorithm or time. The installer
Use cable connector to secure
power cord to cabinet
Power Supply Connector
Power Supply Connector
Power Supply
Use wire ties to secure power cord
to power supply enclosure
Fig. 7 - - Perfect Airt Purifier Electrical Connections
Power Cord
FUSE 3-AMP
EAC-2 TERMINAL
EAC-2
BLW
BHI/LOR
SPARE-1
should use their discretion to select the most appropriate
option based on the initial system static pressure.
Step 3—Maximizing Performance
a. Maximum air purification performance is obtained
when the furnace blower is set for continuous operation
on the thermostat or Evolutiont Control.
Power Indicator
Fig. 8 - - Power Indicator

MAINTENANCE

The Perfect Airt Purifier is designed to require no cleaning.
Maintenance is limited to the replacement of the air purification
cartridge. Frequency of air purifier cartridge replacement may
vary depending on ductwork design and local environmental
conditions.
To replace the air purifier cartridge, complete the following
steps:
6
Sample Furnace Circuit Board
LHT
OFF
DLY
Use terminals to connect the
TEST/TWIN
power cord wires to the furnace
HUM
EAC-1 & 2, & ground terminals
0.5-AMP024 VAC
SEC-1
SEC-2
NEUTRAL-L2
BHT/CLR
BLWR
COOL
1-AMP@115 VAC
SPARE-2
EAC-1
PR-1
HSI
HI LO
EAC-1 TERMINAL
A06030
A06065

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gapaaxbb1625Gapaaxbb2025

Table of Contents