Service And Maintenance Procedures - Bryant 312A Installation, Start-Up, Operating And Service And Maintenance Instructions

2-stage deluxe induced-combustion 4-way multipoise furnace installation, start--up, operating and service and maintenance instructions series 120/c
Table of Contents

Advertisement

(Tabulated Data Based on 21,000 Btuh High- -Heat/14,500 Btuh for Low- -Heat Per Burner, Derated 4% for Each 1000 Ft Above
AVG. GAS
ALTITUDE RANGE
HEAT VALUE
AT ALTITUDE
(FT)
(BTUH/CU FT)
6001 to
U.S.A.
7000
Only
AVG. GAS
ALTITUDE RANGE
HEAT VALUE
(FT)
AT ALTITUDE )
7001 to
U.S.A.
Only
8000
ALTITUDE RANGE
(FT)
U.S.A.
8001 to
Only
9000
AVG GAS
ALTITUDE RANGE
HEAT VALUE
(FT)
AT ALTITUDE
(BTU/CU FT)
U.S.A.
9001 to
Only
10,000
* Orifice numbers 43 are factory installed
SERVICE AND MAINTENANCE
PROCEDURES
WARNING
!
FIRE, PERSONAL INJURY AND UNIT DAMAGE
HAZARD
Failure to follow this warning could result in personal injury,
death and/or property damage.
The ability to properly perform maintenance on this
equipment requires certain knowledge, mechanical skills,
tools, and equipment. If you do not possess these, do not
attempt to perform any maintenance on this equipment other
than those procedures recommended in the User's Manual.
Table 16 - - Orifice Size and Manifold Pressure for Gas Input Rate (cont.)
0.58
Orifice
Manifold
No.
Pressure
675
44
3.5/1.7
700
44
3.3/1.6
725
45
3.7/1.8
750
46
3.6/1.7
775
46
3.4/1.6
800
47
3.6/1.7
825
47
3.4/1.6
850
48
3.7/1.7
0.58
Orifice
Manifold
No.
Pressure
650
44
3.3/1.6
675
45
3.7/1.8
700
46
3.6/1.7
725
47
3.8/1.8
750
47
3.5/1.7
775
48
3.8/1.8
800
48
3.6/1.7
825
48
3.3/1.6
0.58
Orifice
Manifold
No.
Pressure
625
45
3.7/1.8
650
46
3.6/1.7
675
47
3.8/1.8
700
47
3.5/1.7
725
48
3.7/1.8
750
48
3.5/1.7
775
49
3.8/1.8
0.58
Orifice
Manifold
No.
Pressure
600
46
3.6/1.7
625
47
3.7/1.8
650
47
3.4/1.6
675
48
3.6/1.7
700
48
3.4/1.6
725
49
3.7/1.8
Sea level)
SPECIFIC GRAVITY OF NATURAL GAS
0.60
Orifice
Manifold
Orifice
No.
Pressure
No.
43
3.2/1.5
43
44
3.4/1.6
44
45
3.8/1.8
44
46
3.8/1.8
45
46
3.5/1.7
46
47
3.8/1.8
46
47
3.5/1.7
47
48
3.8/1.8
47
SPECIFIC GRAVITY OF NATURAL GAS
0.60
Orifice
Manifold
Orifice
No.
Pressure
No.
44
3.4/1.6
44
45
3.8/1.8
44
46
3.7/1.8
46
46
3.5/1.7
46
47
3.7/1.8
47
47
3.4/1.6
47
48
3.7/1.8
48
48
3.5/1.6
48
SPECIFIC GRAVITY OF NATURAL GAS
0.60
Orifice
Manifold
Orifice
No.
Pressure
No.
45
3.8/1.8
44
46
3.7/1.8
46
46
3.4/1.6
46
47
3.6/1.7
47
48
3.8/1.8
47
48
3.6/1.7
48
48
3.4/1.6
48
SPECIFIC GRAVITY OF NATURAL GAS
0.60
Orifice
Manifold
Orifice
No.
Pressure
No.
46
3.7/1.8
46
47
3.8/1.8
46
47
3.6/1.7
47
48
3.8/1.8
47
48
3.5/1.7
48
49
3.8/1.8
48
WARNING
!
ELECTRICAL SHOCK, FIRE OR EXPLOSION
HAZARD
Failure to follow this warning could result in personal injury
or death, or property damage.
Before servicing, disconnect all electrical power to furnace.
Verify proper operation after servicing.
45
0.62
0.64
Manifold
Orifice
Manifold
Pressure
No.
Pressure
3.3/1.6
43
3.4/1.6
3.5/1.7
43
3.2/1.5
3.3/1.6
44
3.4/1.6
3.7/1.8
45
3.8/1.8
3.6/1.7
46
3.8/1.8
3.4/1.6
46
3.5/1.7
3.6/1.7
47
3.8/1.8
3.4/1.6
47
3.5/1.7
0.62
0.64
Manifold
Orifice
Manifold
Pressure
No.
Pressure
3.5/1.7
43
3.2/1.5
3.3/1.6
44
3.4/1.6
3.8/1.8
45
3.8/1.8
3.6/1.7
46
3.7/1.8
3.8/1.8
46
3.5/1.6
3.6/1.7
47
3.7/1.7
3.8/1.8
47
3.4/1.6
3.6/1.7
48
3.7/1.8
0.62
0.64
Manifold
Orifice
Manifold
Pressure
No.
Pressure
3.3/1.6
44
3.4/1.6
3.8/1.8
45
3.8/1.8
3.5/1.7
46
3.7/1.7
3.7/1.8
46
3.4/1.6
3.5/1.7
47
3.6/1.7
3.7/1.8
48
3.8/1.8
3.5/1.7
48
3.6/1.7
0.62
0.64
Manifold
Orifice
Manifold
Pressure
No.
Pressure
3.8/1.8
45
3.7/1.8
3.5/1.7
46
3.6/1.7
3.7/1.8
47
3.8/1.8
3.4/1.6
47
3.5/1.7
3.6/1.7
48
3.7/1.8
3.4/1.6
48
3.5/1.7