Connecting Contact Closure, Call Reporting
(SMDR), Paging, and Music-On-Hold Devices
Only steps for connection to the processor module are provided here. See the manufacturer's
instructions for more information on installing and using these devices.
Contact Closure Adjunct
1
Insert the modular plug into the Contact Closure jack,
the first jack on the PARTNER ACS processor
module.
2
Route the cord as you did for the line and extension
cords, then connect the other end of the cord to
the jack in the Contact Closure Adjunct.
3
Have a qualified electrician wire the Contact Closure
device or devices to the wiring receptacles in the
other end of the Contact Closure Adjunct. See the
information shipped with the Contact Closure
Adjunct for wiring instructions.
Call Reporting (SMDR) Printer
1
Insert one end of a D8W modular cord into the SMDR
jack, the second jack on the PARTNER ACS
processor module.
2
Plug the other end of the cord into a 355A adapter,
then plug the adapter into the printer's RS-232C
serial port.
Paging System
If you connect a paging system from a manufacturer
other than Lucent Technologies, a paging interface may
be required.
1
Insert the modular plug into the PAGE jack on the
PARTNER ACS processor module (located near
the middle of the processor, just above the line
jacks).
2
Route the cord as you did for the line and extension
cords, then connect the other end of the cord to
the paging system.
22
Installation Procedures
Contact
Closure Jack
Contact
Closure
Adjunct
00
NE R 30
jun ct
PA RT
su re Ad
ct Clo
Co nta
SMDR Jack
Call Accounting
Terminal Printer
PAGE Jack
Paging System