Central Office Network Interface Codes - Lucent Technologies MERLIN LEGEND Release 6.1 Installation Manual

Release 6.1
Hide thumbs Also See for MERLIN LEGEND Release 6.1:
Table of Contents

Advertisement

MERLIN LEGEND Communications System Release 6.1
Installation 555-661-140
Connecting the Control Unit to the Network Interface
Wiring
facilities. These codes are shown in Table 4–2, by trunk type and
adapter type.
Table 4-2.

Central Office Network Interface Codes

Trunk Type
LS central office trunk
GS central office trunk
DID
OPS
Tie trunk
BRI
DS1
NOTE:
The preferred network interface is the RJ48X. If a customer's site
uses the RJ48X interface and the customer's equipment does not
provide connection, the T1 trunk's receive pair is looped back to the
transmit pair. This simplifies troubleshooting the T1 trunk from the
central office.
In most installations, the network interface is connected through a
cross-connect field to the control unit. However, for systems with
fewer than 24 extensions, you can connect the trunk wires directly
to the control unit.
When constructing wiring fields between the network interface and the
control unit, you must order hardware as individual parts. Do not use
Interconnect Wiring or Systimax wiring kits.
Federal Interface
Code for Trunk
02LS2
02GS2
02RV2-T
OL13C
TL31M
02B1Q
04DU9-B
04DU9-C
Network Interface
RJ11C, RJ14C, RJ21
RJ11C, RJ14C, RJ21
RJ11C, RJ14C, RJ21
RJ11C
RJ2GX
RJ11C, RJ14C, RJ21
RJ48C/X
See note below.
Issue 1
August 1998
Page 4-4