Circuit Breaker
The circuit breaker will automatically switch OFF if there is a short circuit or a
significant overload of the generator at the receptacle. If the circuit breaker is
switched OFF automatically,
check that the applicance is working properly
and does not exceed the rated load capacity of the circuit before switching the
circuit breaker ON again.
The circuit breaker may be used to switch the generator power ON or OFF.
Ground Terminal
The gernerator ground terminal is connected to the frame of the generater, the
metal non-current carrying parts of the generator, and the ground terminals of
each receptacle.
Before using the ground terminal, consult a qualified electrician,
electrical
inspector or local agency having jurisdiction for local codes or ordinances that
apply to the intended use of the generator.
AC CIRCUIT BREAKER
GROUND TERMINAL
Oil Alert System
The Oil Alert system is designed to prevent engine damage caused by an
insufficient amount of oil in the crankcase. Before the oil level in the crankcase
can fall below a safe limit, the Oil Alert system will automatically
stop the
engine (the engine switch will remain in the ON position). If the engine stops
and will not restart, check the engine oil level (p. 24) before troubleshooting
in
other areas.
OIL FILLER HOLE
UPPER
LEVEL
\