Installation Instructions; Specifications; Product Specifi Cation - Danfoss TP5000 si range Installation And User Instructions Manual

Electronic 5/2 day programmable room thermostat mains, battery and rf versions
Hide thumbs Also See for TP5000 si range:
Table of Contents

Advertisement

Installation Instructions

Please Note:
This product should only be installed by a qualifi ed electrician
or competent heating installer and should be in accordance
with the current edition of the IEEE wiring regulations.

Product Specifi cation

Thermostat features
Power supply
Memory back-up
Temperature Range
Sensing
Factory set calendar
clock
Switching action of
output relay
Transmission frequency
(RF models)
Transmission range
(RF models)
Remote sensor inputs
(A models only)
Dimensions (mm)
Design standard
Rated impulse voltage
Ball hardness test
Control pollution
situation
Temperature accuracy
Time accuracy
Important note RF products: Ensure that there are no large metal objects, such as boiler cases
or other large appliances, in line of sight between the transmitter and receiver as these will
prevent communication between thermostat and receiver.
TP5000 Si TP5000-RF Si
2 x AA/MN1500/LR
alkaline cells
Retained for life of product
Automatic summer/winter time change
3(1)A,
N/A
10-230V
N/A
433.92MHz
N/A
30m max.
Can be set by installer for remote temperature sensor,
limit sensor, window contact or telephone activated
110 wide, 88 high, 28 deep
EN60730-2-9 (EN300220 for RF)
±1 minute per month
TP5000M Si TP5000M 24 Si
230V, ±15%,
50Hz
5-30°C
3(1)A, 10-230V, Type 1B
N/A
N/A
switch contacts
2.5kV
75°C
Degree 2
±1°C
GB
24V, ±15%,
50Hz
N/A
N/A
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tp5000m siTp5000m 24 siTp5000-rf