Before programming the thermostat press the + & – AND ∧ ∧ ∧ ∧ ∧ and ∨ ∨ ∨ ∨ ∨ buttons
simultaneously to reset the unit (Fig.1)
Setting the Clock and Day
Press PROG (Fig.2) to begin programming
Use + or – buttons (Fig.3) to adjust the TIME (Fig.4)
Press PROG again (Fig.2)
Use + or – buttons (Fig.3) until correct DAY is shown (Fig.5)
(1 = Monday, 2 = Tuesday, etc)
Accepting the Factory Pre-settings
The TP5000 has pre-set times already programmed in, which often suit most
people (see Table below).
To accept these settings close the front cover and after 2 minutes the pre-
settings will automatically be accepted.
Mon-Fri
Event
Time
Temp°C
1
06.30
2
08.30
3
11.30
4
13.30
5
16.30
6
22.30
To adjust the factory pre-settings & set your own time and
temperature programmes
For Days 1-5 (weekdays)
a) Press PROG (Fig.2) 3 times to show the 1
(Event 1 Days 1,2,3,4,5) (Fig.6)
b) Use + or – buttons (Fig.3) to adjust the TIME (press and hold to change in
10 min increments)
c) Use ∧ ∧ ∧ ∧ ∧ or ∨ ∨ ∨ ∨ ∨ buttons (Fig.7) to adjust the TEMPERATURE
d) Press PROG (Fig.2) to move to next preset time & temp (Event 2) (Fig.8)
e) Repeat steps b, c & d for programming Events 3, 4 5 & 6
For Days 6-7 (weekends)
Press PROG (Fig.2) to show 1
G
Days 6-7) (Fig.9)
Repeat steps b, c and d above to programme time and temperature events
G
for the weekend
Returning to RUN mode
Press PROG (Fig.2) – the colon in the LCD display will start to flash (Fig.10)
TP5000
User Instructions
Sat-Sun
Event
20
1
15
2
20
3
15
4
21
5
15
6
st
pre-set time and temperature
st
pre-set time and temperature (Event 1
Time
Temp°C
07.00
20
16.00
21
23.00
15
00.00
15
01.00
15
01.59
15
Fig.1
Fig.2
Fig.3
i2 00
Fig.4
Fig.5
1
1
6 30
Fig.6
1 2 3 4 5
Fig.7
2
8 30
Fig.8
1 2 3 4 5
Fig.9
1
7 00
Fig.10
i2 24
1
20
15
20
6 7
20

Advertisement

loading

Summary of Contents for Danfoss TP5000

  • Page 1 (1 = Monday, 2 = Tuesday, etc) Fig.2 Accepting the Factory Pre-settings The TP5000 has pre-set times already programmed in, which often suit most people (see Table below). Fig.3 To accept these settings close the front cover and after 2 minutes the pre- settings will automatically be accepted.