3.6.29 UCC-128

Type / properties:
Linear code
Activation sequence:
<Esc>(s24710T<Base Data><Stop Character>
For an explanation on selecting the stop character and the optional parameters, see
chapters 3.2.1. and 3.2.6.
Default - parameters:
v parameter
p parameter
b parameter
Additional properties:
Size of base data:
Character set:
Example:
<Esc>(s24710T123456789012345<CR>
29
1
6,12,18,24
15 to 21
0 to 9
93