Scanning for New Drives

The Intel
storage devices and displays icons for them on the main screen. If the Intel
Console 2 does not detect a new drive, you can use the Scan for Foreign Configuration
option to find it. To do this, follow these steps:

Rebuilding a Drive

If a single drive in a fault tolerant system fails, the system is protected from data loss by the
parity data (in RAID 5, RAID 50, or RAID 60) or by data redundancy (RAID 1, RAID 10).
You must replace the failed drive and rebuild the drive's data on a new drive to restore the
system to fault tolerance. (Or, if the drive is still operational, you can rebuild the data on the
failed drive.) If dedicated or global hot-spare disks are available, the failed drive is rebuilt
automatically without any user intervention.
If a drive has failed, a red circle is displayed to the right of the disk drive icon:
A small yellow circle is displayed to the right of the icon of the virtual disk that uses this
physical disk:
still intact.
If you need to rebuild a physical drive, follow these steps:
142
®
RAID Web Console 2 normally detects newly installed disk drives and other
1. Select a controller icon in the left panel.
2. Select Go To -> Controller -> Scan Foreign Configuration.
®
If the Intel
RAID Web Console 2 detects any new disk drives, it displays a list of them
on the screen.
. This indicates that the virtual disk is in a degraded state, but the data is
1. Right click the icon of the failed drive and select Rebuild.

Figure 91. Scan for Foreign Configuration

®