2.2 Installation of the Hybrid IP-PBX
2.2.8

Wall Mounting (KX-TDA600/KX-TDA620)

Mounting Shelves
CAUTION
Make sure that the wall the shelves will be attached to is capable of supporting at least 4 times the
weight of the shelves.
Drive mounting screws into the wall. Be careful to avoid touching any metal laths, wire laths or
metal plates in the wall.
Notes
Make sure to remove the front cover from each shelf before installing the shelves (refer to "2.2.3
Opening/Closing the Front Cover").
Do not install any optional service cards or a PSU in the shelves before installation.
Do not block the openings of the shelf. Allow space of at least 20 cm (8 in) above and 10 cm (4 in)
at the sides of the shelf.
Make sure that the surface behind the shelf is flat and free of obstacles, so that the openings on
the back of the shelf will not be blocked.
Make sure that the surface behind the shelf is not made of wood.
Be careful not to drop the shelf.
1.
Install 4 anchor plugs in the wall, using the metal bracket as a template. Fix the metal bracket with 4
screws (A).
Anchor Plug
Metal Bracket
Screw (A)
96
Installation Manual
W a ll
Hammer
Screw (A)
Metal Bracket
Anchor Plug
8 mm
(5/16 in)
30 mm
(1-3/16 in)