v To order additional microprocessor options, contact your IBM reseller or IBM
v When you install the microprocessor in socket J6, you must also install the
v The microprocessor speeds are automatically set for this server; therefore, you
v If you need to replace a microprocessor, call for service.
v If your server supports a 400 MHz front-side bus, install only a microprocessor
v If the thermal-grease protective cover (for example, a plastic cap or tape liner) is
v Do not remove the first microprocessor from the system board to install the
The following illustration is a simplified layout of the microprocessor connector
locations and other microprocessor-related components on the system board.
60
xSeries 345 Type 8670: Hardware Maintenance Manual and Troubleshooting Guide
marketing representative.
voltage regulator module (VRM) that comes with the microprocessor in VRM
connector J5.
do not need to set any microprocessor frequency-selection jumpers or switches.
with one pin missing from one corner and two pins missing from an adjacent
corner. If your server supports a 400 MHz front-side bus, the heat-sink retention
mechanism surrounding the microprocessor connector is metallic gray.
400 MHz front-side bus
microprocessor
If your server supports a 533 MHz front-side bus, install only a microprocessor
with one pin missing from each of two adjacent corners. If your server supports a
533 MHz front-side bus, the heat-sink retention mechanism surrounding the
microprocessor connector is black.
removed from the heat sink or fan sink, do not touch the thermal grease on the
bottom of the heat sink or fan sink or set down the heat sink or fan sink.
Note: Removing the heat sink or fan sink from the microprocessor destroys the
even distribution of the thermal grease and requires replacing the thermal
grease. Setting down the heat sink or fan sink onto any surface when the
thermal-grease protective cover is removed will contaminate the thermal grease.
If the thermal grease becomes contaminated with particles, it must be replaced.
For information about replacing contaminated thermal grease on the heat sink or
fan sink, contact IBM Integrated Technology Services. For the most up-to-date
phone numbers, go to http://www.ibm.com/planetwide/, or in the U.S. and
Canada, call 1-800-IBM-SERV (1-800-426-7378).
Have the following information ready when you call:
– Machine type and model
– Serial number of your server
second microprocessor.
533 MHz front-side bus