Maytag MGDE300VF - Performance Series 27-in Gas Dryer Use And Care Manual page 6

Use and care guide
Hide thumbs Also See for MGDE300VF - Performance Series 27-in Gas Dryer:
Table of Contents

Advertisement

Available languages

Available languages

Dryer
Dimensions
Explosion
Hazard
Keep flammable
materials
and vapors,
such as
gasoline,
away from dryer.
Place dryer at least 18 inches (46 cm) above the floor
for a garage installation.
Failure to do so can result in death, explosion,
or fire.
You will
need
A location
that allows
for proper
exhaust
installation.
A gas dryer must be exhausted
to
the outdoors.
See "Venting
Requirements."
A grounded
electrical
outlet
located
within
2 ft (61 cm) of either side of the dryer. See
"Electrical
Requirements."
A sturdy floor
to support
the total dryer weight
of 200 Ibs (90.7 kg). The combined
weight
of a companion
appliance
should
also be considered.
A level floor with
a maximum
slope of 1" (2.5 cm) under entire
dryer. If slope is greater
than 1" (2.5 cm), install Extended
Dryer Feet Kit, Part Number
279810.
Clothes
may not
tumble
properly,
and automatic
sensor cycles may not operate
correctly
if dryer is not
[eve[.
For a garage installation,
you will
need to place the dryer at least 18" (46 cm) above the
floor.
If using a pedestal,
you will need 18" (46 cm) to the bottom
of the dryer.
Do not operate
your dryer at temperatures
below
45°F (7°C). At lower temperatures,
the dryer
might not shut off at the end of an automatic
cycle. This can result in longer drying
times.
The dryer must not be installed
or stored in an area where
it will
be exposed
to water and/or
weather.
Check code requirements.
Some codes limit, or do not permit,
installation
of the dryer in
garages, closets, mobile
homes or sleeping
quarters.
Contact
your
local building
inspector.
NOTE: No other fuel-burning
appliance
can be installed
in the same closet as a dryer.
38"
(96.52 cm)
*Most installations
require a minimum
5" (12.7 cm) clearance
behind
the dryer for the
exhaust
vent with elbow.
See "Venting
Requirements."
Installation
spacing
for recessed
area or closet
installation
The following
spacing dimensions
are recommended
for this dryer. This dryer has been tested
for spacing
of 0" (0 cm) clearance
on the sides and rear. Recommended
spacing
should
be
considered
for the following
reasons:
Additional
spacing should
be considered
for ease of installation
and servicing.
Additional
clearances
might be required
for wall,
door and floor
moldings.
Additional
spacing should
be considered
on all sides of the dryer to reduce
noise transfer.
For closet installation,
with
a doo_; minimum
ventilation
openings
in the top and bottom
of the door are required.
I.ouvered
doors with equivalent
ventilation
openings
are
acceptable.
Companion
appliance
spacing
should
also be considered.
Custom
undercounter
installation
- Dryer only
Installation
clearances
The location must be large enough to allow the dryer door to open fully.
1"* ---_ I-_---27"--_11_-
1"*
(2.5cm)
(68.6 cm)
(2.5cm)
*Required
spacing