v Communication error to the blade or user doesn't have permission for OFM on a
blade.
v HBA firmware needs to be upgraded to support OFM.

Parsing errors

This table contains a list of the parsing errors that can be generated when
processing the OFM configuration file, with an explanation of the cause of each
error.
Table 11. Parsing errors
Error message
Assuming boot type `None`
Assuming mode `Ignore`
Attempt to add multiple boot targets to a
blade with the same priority
Attempt to redefine slot
Attempt to use a slot that has not yet been
defined
Attempt to write non-Ethernet data to
Ethernet port
Bad boot type
Bad entry type
Bad IP address
Bad offset number
Bad port number
Bad slot number
Bad target priority - must be first or second
Description
The "Boot Type" field has been left empty –
the system will assume a value of "none"
and continue processing the line.
The "Mode" field has been left empty – the
system will assume a value of "Ignore" and
continue processing.
A single priority value for a target can only
be used once for a given slot.
There are multiple lines defining a slot. A
slot must be defined before it is used and
cannot be defined more than once.
A slot must be defined before it used. The
OFM configuration file contains a reference
to a slot that has not been defined when
referenced.
The OFM configuration file includes an
attempt to define a non-Ethernet port to an
Ethernet-only port number (1 or 2).
The "Boot type" string cannot be parsed.
The entry type (One of: BladeCenter, Slot,
Eth, FC, FCTarget) was not recognized.
The IP address was incorrectly formed or, in
the case of a hostname, the DNS lookup
failed.
Cannot parse the offset number, or the
number is out of range. (Offsets must be in
the range 0-3)
Cannot parse the port number, or the
number is out of range. (Ports must be in
the range 1-8 for Ethernet ports or 3-8 for all
other types)
Cannot correctly parse the slot number or it
is out of range. The exact range depends on
the BladeCenter type (BCH, BCS, BCHT),
but is never less than 1 or more than 14.
This error can also occur when the slot field
does not have a closing comma.
Cannot parse the target priority, or it was
out of range (first/second). Targets can only
be set as the first or second priority.
Chapter 6. Troubleshooting