Check t hatleveling l egsarefirmlyagainst thefloor.
Close andlatch thedoor, a ndplace level a gainst the
frontpanel. Check t hatdishwasher iscentered f romfront
toback intheopening. If needed, adjust l eveling l eguntil
dishwasher isplumb. R epeat forother s ideofdishwasher.
Helpful "13p: Push uponfrontofdishwasher to raise
dishwasher offtheground toadjust f rontlegs. W ith
someinstallations, it maybeeasier to adjust t hefrontleg
using the3/16" h exhead socket or adjustable wrench.
Place level a gainst topfrontopening oftub.Check t hat
dishwasher is level f romsidetoside. I f dishwasher is not
level, a djust f rontlegsupor downuntildishwasher is
level.
Connect
to Water Supply
Copper tubing only: Slide nut then ferrule
onto copper tubing
about 1" (2.5 cm).
NOTE: To avoid vibration
during
operation,
route the
water supply
line so that it does not touch the
dishwasher
base, frame or motor.
Copper tubing
only: Put the tubing
into the 90 ° elbow
fitting
as far as it will go (the copper tubing
bends and
kinks easily). Slide the nut and ferrule forward
and start
the nut onto the elbow threads.
Flexible
braided connection:
Secure nut to elbow
using
5/8" open ended wrench or adjustable
wrench.
NOTE: Do not use Teflon ® tape with compression
fittings.
Hold the 90 ° elbow fitting still with one adjustable
wrench
and tighten the nut with second adjustable
wrench.
Helpful
"l]p: Use a 5/8" open
ended
wrench
for easier
access
to tighten
connection.