Illegible Characters
Display on the
Terminal after
Power-On
If the system operates normally after the system runs the power-on self-test
(POST), the start-up information is displayed on the console terminal. If the
configuration system has a fault, the terminal may display only illegible characters.
If the console terminal displays illegible characters after the POST, verify that the
HyperTerminal parameters are set properly, as follows:
Baud: 9600
Data bits: 8
Stop bit: 1
Parity: None
Flow control: None
Terminal emulation: VT100
If the parameter settings do not match these values, reconfigure them.