Recommend To Install Following Raid Controllers In Pci Slot Other Than Slot 4 - Intel S5000PSLROMB Hardware Manual

Server/workstation board and server system tested hardware and operating system list
Table of Contents

Advertisement

Intel® Server Boards S5000PSL/S5000XSL, Intel® Workstation Board
S5000XVN, and Intel® Server System SC5400RA
13. Type "mount /dev/sdb /temp".
14. Type "ls /temp"
All the driver files are now in /temp.
15. Type "cd temp" to go to /temp directory.
16. Type "./replace_ahci.sh" to execute the file.
This removes ahci from /etc/modprobe.conf and blacklists ahci in
/etc/modprobe.d/blacklist.
17. Go back to the graphic screen and reboot the system in order to finish the
installation.
Status:
ESRTII driver ver. 10.21.0507.2008 now has the updated release notes.
6.5
Recommend to install following RAID Controllers in PCI Slot other than
Slot 4
®
Issue:
Intel
and SRCSASLS4I may fail to activate RAID BIOS Console by Ctrl+G after they
are installed into PCI Slot 4 on the Intel
S5000VSA, or Intel
Guideline:
Install the RAID controller in a different PCI Express Slot.
Status:
This issue was resolved with BIOS R0094.
Revision 2.9
RAID Controllers SRCSASJV, SRCSASRB, SRCSATAWB, SRCSASBB8I
®
Workstation Board S5000XVN.
®
Server Boards S5000PSL, S5000XSL,
Installation Guidelines
63