Configure The Settings Relating To The Alarm Output Terminal [Alarm] - Panasonic WV-SC384 Operating Instructions Manual

Network camera
Hide thumbs Also See for WV-SC384:
Table of Contents

Advertisement

Configure the settings relating to the alarm output terminal
[Alarm]
Click the [Alarm] tab on the "Alarm" page. (☞ Pages 26 and 27: How to display/operate the setup menu)
The settings relating to the alarm output terminal can be configured in this section.
■ Alarm output terminal setup
[Alarm output trigger]
Select "On" or "Off" to determine whether or not to out-
put the alarm signals to the alarm output terminal when
an alarm is detected.
Default: Off
[Alarm output type]
Select "Latch" or "Pulse" for the alarm output terminal
at an alarm occurrence.
Latch: When an alarm is detected, the alarm output
terminal will be in the state selected for "Trigger out-
put" until the alarm occurrence indication button is
clicked.
Pulse: When an alarm is detected, the alarm output ter-
minal will be in the state to the "Trigger output" set-
ting for the period set for "Pulse width". When the
alarm occurrence indication button is clicked, the
alarm output terminal will return to the normal state.
Default: Latch
[Trigger output]
Select "Open" or "Close" to determine whether to open
or close the alarm output terminal when outputting the
alarm signals.
Open: The alarm output terminal will open when out-
putting the alarm signals. (Normally close)
Close: The alarm output terminal will close when out-
putting the alarm signals. (Normally open)
Default: Close
Note:
• When "Open" is selected, the alarm signal will be
output for around 20 seconds when the power of
the unit is turned on.
[Pulse width]
When "Pulse" is selected for "Alarm output", select an
alarm output terminal duration from the following.
Available range: 1-120s
Default: 1s