HP D5970A - NetServer - LCII Manual page 14

Mass storage upgrade kit guide
Hide thumbs Also See for D5970A - NetServer - LCII:
Table of Contents

Advertisement

Chapter 2
WARNING
To prevent the rack from tipping over, extend the anti-tip foot
or attach the anti-tip feature before extending the NetServer
from the rack. Also lower the leveler feet of the rack to
improve stability and to prevent the rack from rolling. Failure
to use the anti-tip foot or feature and the leveler feet could
result in serious injury.
2. If there is a door on the rack, remove it.
3. The NetServer uses a chassis retention bracket (steel z-bracket) to secure
the rear of the NetServer to the rack assembly. Unscrew the NetServer from
the chassis retention bracket by removing the two screws shown in
Figure 2-2. Leave the bracket attached to the rack column.
Figure 2-2. Unscrew NetServer from Chassis Retention Bracket
(Shown for HP NetServer LH 3r; Number of Power Supply Modules May Vary)
4. Clips attach the front bezel to the NetServer chassis. To remove the bezel,
simply pull it toward you until it comes free, as shown in Figure 2-3.
10
Installation
Remove the Two Screws
That Fasten the NetServer
to the Chassis Retention
Bracket