Chapter 4
NOTE
If the Battery Backup Unit is not installed or connected on the
FCArray Controller card, an error message will appear instead
of the dialog box shown in Figure 4-26.
If this is for the initial installation of the Rack Storage/12FC,
the first time the FCArray Controller card is used, or a new
BBU (battery pack) has been installed, the battery pack must
be reconditioned before using the FCArray Controller card.
The Reconditioning Battery process may take up to 15 hours to
complete.
The dialog box is divided into three groups, which are described in the items listed
under the following sections:

Power Levels

Low Power Threshold - This indicates a preset power level, expressed
as hours or minutes of charge, and is used to trigger an alarm. An alarm
is triggered, when the battery pack's Current Power value drops below
the setting in this field. This field is edited to change the existing value
and then verified and applied to accept the change. Refer to Set Low
Power Threshold under the Actions bullet for more information.
58
Figure 4-26. Intelligent BBU Dialog Box