Lenovo ThinkServer RD240 Hardware Maintenance Manual page 84

Hardware maintenance manual
Hide thumbs Also See for ThinkServer RD240:
Table of Contents

Advertisement

7. Position the RAID controller near the riser card assembly. Ensure that the left edge of the RAID controller
is inserted into the notch of the RAID card retention bracket
straight down into the PCI card slot 1
RAID controller.
Figure 49. Installing the RAID controller into the PCI card slot 1 on the riser card assembly
Note: There are three PCI card slots on the riser card assembly as shown in the illustration. The PCI
card slot 1
2
is for RAID cards only. For more information about the PCI card slots, see "Installing a
PCI card" on page 55.
8. Install the riser card with the RAID controller into an appropriate PCI card slot on the system board.
9. Connect the other end of the two 400 mm (15.75 inches) mini SAS signal cables to the backplane of
your server.
Figure 50. Mini SAS signal cable connectors on the backplane
a. For one mini SAS signal cable, connect the other end to the mini SAS signal cable connector
the backplane.
b. For the other mini SAS signal cable, connect the other end to the mini SAS signal cable connector
1
on the backplane.
72
ThinkServer RD240 Hardware Maintenance Manual
1
2
until it is securely seated. Then install the screw
, and then firmly insert the RAID controller
3
to secure the
2
on

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents