82
A
A: S
PPENDIX
AFETY
Power Cord Set — Japan
Important Safety Information
I
NFORMATION
urządzenia należy uważnie przeczytać poniższe informacje o
bezpieczeństwie.
WARNING: Installation and removal of the unit must be carried out by
qualified personnel only.
WARNING: If installing the Switch 5500 together (one on top of the
other) with SuperStack II or SuperStack 3 units that are shallower than
the 5500, the Switch 5500 unit must be installed below the shallower
units.
WARNING: The unit must be earthed (grounded) or must be connected
to an earthed power supply to ensure compliance with safety standards.
WARNING: Power Cord Set:
This must be approved for the country where it is used:
U.S.A. and
Canada
United
Kingdom only
The cord set must be UL-approved and CSA certified.
■
The minimum specification for the flexible cord is:
■
No. 18 AWG
Type SV or SJ
3-conductor
The cord set must have a rated current capacity of at least
■
10A.
The attachment plug must be an earth-grounding type
■
with a NEMA 5-15P (15A, 125V) or NEMA 6-15P (15A,
250V) configuration.
The supply plug must comply with BS1363 (3-pin 13 amp)
■
and be fitted with a 5A fuse which complies with BS1362.
The mains cord must be <HAR> or <BASEC> marked and
■
be of type H03VVF3GO.75 (minimum).