Chapter 9 CLEANING AND INSPECTION

Chapter 9 CLEANING AND INSPECTION
Turn off the power switch before starting any cleaning work, otherwise the machine may operate if the foot
switch is depressed by mistake, which could result in injury.
Be sure to wear protective goggles and gloves when handing the lubricating oil and grease, so that they do
not get into your eyes or onto your skin, otherwise inflammation can result.
Furthermore, do not drink the oil or eat the grease under any circumstances, as they can cause vomiting
and diarrhoea. Keep the oil out of the reach of children.

1. Rotary hook

Screw

2. Eye guard

47
CAUTION
q
Screw
w
BAS-364E, 366E, 370E, 375E
1. Remove the two screws q, and remove needle plate
w.
2. Remove pieces of thread and other foreign matter from
around the rotary hook.
3. After cleaning, install the needle plate w with the two
screws q.
Wipe the eye guard clean with a soft cloth.
Note
Do not use solvents such as kerosene thinner to clean
the eye guard.