GL
MODEL SL585
HEAVY DUTY SLIDE GATE OPERATOR
MODEL SL595
HEAVY DUTY, HARSH ENVIRONMENT
SLIDE GATE OPERATOR
2 YEAR WARRANTY
Serial # ________________________
(located on electrical box cover)
MODELS SL585 AND SL595 ARE FOR VEHICULAR
Installation Date __________________
PASSAGE GATES ONLY AND ARE NOT INTENDED FOR
PEDESTRIAN PASSAGE GATE USE

Advertisement

Table of Contents
loading

Summary of Contents for Chamberlain LiftMaster Professional SL585

  • Page 1 HEAVY DUTY, HARSH ENVIRONMENT SLIDE GATE OPERATOR 2 YEAR WARRANTY Serial # ________________________ (located on electrical box cover) MODELS SL585 AND SL595 ARE FOR VEHICULAR Installation Date __________________ PASSAGE GATES ONLY AND ARE NOT INTENDED FOR PEDESTRIAN PASSAGE GATE USE...
  • Page 2: Table Of Contents

    WARNING WARNING Pad Mounting (SL585 only) ......9 Electrical Post Mounting (SL585 & SL595) ..... . . 10...
  • Page 3: Operator Dimensions And Horsepower Chart

    O P E R A T O R D I M E N S I O N S A N D H O R S E P O W E R C H A R T MODEL SL585 28.9" • 1/2 HP Motor (73.4 cm)
  • Page 4: Ul325 Model Classifications

    UL325 ENTRAPMENT PROTECTION REQUIREMENTS SAFETY ACCESSORY SELECTION GATE OPERATOR ENTRAPMENT PROTECTION All UL325 compliant LiftMaster gate operators will accept external entrapment protection devices to protect people from motorized UL325 Slide Gate Operator Swing &...
  • Page 5: Safety Installation Information

    S A F E T Y I N S T A L L A T I O N I N F O R M A T I O N 1. Vehicular gate systems provide convenience and security. Gate systems are comprised of many component parts. The gate operator is only one component.
  • Page 6: Suggested Entrapment Protection Device Locations

    S U G G E S T E D E N T R A P M E N T P R O T E C T I O N D E V I C E L O C A T I O N S GATE SYSTEM (MASTER/SECOND SLIDE GATE) Open Edge...
  • Page 7: Safety Precautions For Open Roller Gates

    SAFETY PRECAUTIONS FOR OPEN ROLLER GATES Gate Edge on Fence Gate Edge on Post for Open Direction Gate Edge on Rear of Gate for WARNING WARNING WARNING Leading Edge of Gate Open Direction for Close Direction • Injuries occur when people get their hands or feet caught CAUTION between the top or bottom of the gate and the gate roller.
  • Page 8: Wiring

    W I R I N G WARNING WARNING WARNING To reduce the risk of SEVERE INJURY or DEATH: • DO NOT install ANY wiring or attempt to run the operator without consulting the wiring diagram. We recommend that • ANY maintenance to the operator or in the area near the you install an optional reversing edge BEFORE proceeding operator MUST NOT be performed until disconnecting the with the control station installation.
  • Page 9: Installation

    I N S T A L L A T I O N PAD MOUNTING (SL585 ONLY) Figure 1 RETRO-FIT INSTALLATION The operator is shipped from the factory with the lower mounting angles configured out (Figure 1). If you have pad constrictions, either angle can be unbolted and reversed to angle in.
  • Page 10: Post Mounting (Sl585 & Sl595)

    POST MOUNTING (SL585 AND SL595) RETRO-FIT INSTALLATION Figure 1 The operators come from the factory configured to mount to an inside the frame post mount dimension of 26" (66 cm) (outside to outside of posts). The frame comes slotted to accommodate posts 24-1/8"...
  • Page 11: Install Gate Bracket And Drive Chain

    WARNING WARNING INSTALL GATE BRACKET AND DRIVE CHAIN CAUTION CAUTION WARNING Figure 1 “Outside” Gate To prevent damage to the operator or gate, DO NOT drive the “Inside” limit (nuts) actuators on the shaft past their normal positions. 1. Mount gate brackets to the vertical front and rear posts of the gate (Figure 1).
  • Page 12: Available Conduit Access For The Electrical Box

    On three phase operators, power connections must be properly phased. If phased incorrectly, the gate operator will run reversed. To correct this situation, shut off power at main power source and at the operators electrical disconnect switch. Then reverse any two of the three power leads. MANUAL DISCONNECT MODEL SL585 MODEL SL595 DISENGAGEMENT: Rotate disconnect handle 90˚ to...
  • Page 13: Adjustment

    A D J U S T M E N T LIMIT SWITCH ADJUSTMENT WARNING WARNING NOTE: Make sure the limit nuts are positioned between the limit switch actuators before proceeding with adjustments. To reduce the risk of SEVERE INJURY or DEATH: CAUTION 1.
  • Page 14: Install Vent Plug

    INSTALL VENT PLUG 1. Disconnect power. 2. Remove the pin from the vented plug. 3. Reconnect power. MODEL SL595 MODEL SL585 UL325 ENTRAPMENT PROTECTION GL Board Force Control PRIMARY ENTRAPMENT PROTECTION ADJUSTMENTS Max. Force Control Set the force control pot such that the unit will complete a full cycle of gate travel but can be reversed off an obstruction without applying an unreasonable amount of force.
  • Page 15: Control Board Illustration

    UL325 ENTRAPMENT PROTECTION (CONTINUED) EDGE/PHOTO OPEN EDGE/PHOTO CLOSE This switch (S2-3) selects edge or photo sensor for the gate This switch (S2-4) selects edge or photo sensor for the gate opening protection input. closing protection input. PHOTO OPEN PHOTO CLOSE Open Photo Eye (Pause): When the Close Photo Eye (Reverse): When the control board is configured for photo...
  • Page 16: Program Settings

    PROGRAM SETTINGS (DIP SWITCH S1) NOTE: For all S1, S2 and S4 switch settings to take effect, the Save Mode switch must be set to the off position. TIMER-TO-CLOSE TIMER-TO-CLOSE ENABLE This switch enables the auto close timer. The Timer-to-Close feature works in conjunction with the potentiometer located on Max.
  • Page 17: Control Connection Diagrams

    CONTROL CONNECTION DIAGRAMS Accessory Terminal Block Accessory Terminal Block 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 24 Vac Accessory Power May Be Found On These Terminals 24 Vac Soft Open Input (N.O.) Close Override Control...
  • Page 18: Radio Receiver

    24 Vac Power (from radio block R4) to Terminal Block TB1 position 1. 24 Vac Accessory Power can be found at terminals R1 and R2 located on radio terminal block. The LiftMaster Radio Receiver comes pre-wired to the operator Antenna Connector WARNING WARNING •...
  • Page 19: Accessory Wiring

    PROGRAMMING THE REMOTE TO THE RECEIVER Figure 2 1. Pry open the front panel of receiver case with a coin or a CONSTANT MOMENTARY screwdriver. Re-connect power to operator (Figure 3). Jumper Jumper OPERATION OPERATION 2. Press and release the “learn” button on the receiver. The learn Output Output indicator light will glow steadily for 30 seconds.
  • Page 20 ACCESSORY WIRING (CONTINUED) Open Override Terminals 7 & 5 (Com) - Hard Open Override Control Input Control Input 3 4 5 6 7 8 These terminals are intended for use only with the open control of a 3-button station that is installed within line of sight of the gate. N.O.
  • Page 21: Earth Ground Rod Installation

    EARTH GROUND ROD INSTALLATION WARNING WARNING Proper grounding gives an electrical charge, such as from an electrical static discharge or a near lightning strike, a path from To AVOID damaging gas, power or other underground utility which to dissipate its energy safely into the earth. lines, contact underground utility locating companies BEFORE CAUTION digging more than 18"...
  • Page 22: Sequenced Access Management System . . . . . . . . . . . . . . . . . 22 Attention

    3 on the BG770 barrier gates terminal strip. b) Use a loop system to close the barrier gate after the vehicle 6. Attach a wire from terminal 5 of the SL585/595 accessory has passed through the SAM system.
  • Page 23: Operation And Maintenance

    After adjusting the maintenance. force or the limit of travel, retest the gate operator. AVERTISSEMENT 9. ALL maintenance MUST be performed by a LiftMaster Failure to adjust and retest the gate operator properly professional. can increase the risk of INJURY or DEATH.
  • Page 24: Solenoid Actuated Brake

    Anytime the motor is running, the electric solenoid physically releases the brake. A solenoid brake is standard on SL585/595 operators. The brake is adjusted at the factory and should not need additional adjustment for the life of the friction pad.
  • Page 25: Force Control

    CONTROL BOARD PROGRAMMING AND FEATURES (CONTINUED) FORCE CONTROL LED Code Diagnostic Meaning Cleared By Flashed Set the force control pot such that the unit will complete a full cycle of gate travel but can be reversed off an obstruction without Normal operation applying an unreasonable amount of force.
  • Page 26: Troubleshooting

    T R O U B L E S H O O T I N G FAULT POSSIBLE CAUSE OPERATOR FAILS TO RUN 1) Improper wired stop control Check the green LED (D17) on control board. If the green LED is off, ➤...
  • Page 27 T R O U B L E S H O O T I N G FAULT POSSIBLE CAUSE MASTER OR SECOND 1) Failure to cycle power after setup ➤ The power to each unit must be cycled in order to initiate proper OPERATOR IS NOT master/second communication if the operators were previously in FUNCTIONING PROPERLY...
  • Page 28: Self-Regulating Heater Accessory

    SELF-REGULATING HEATER ACCESSORY The heater kits are thermostatically controlled heaters that are utilized in areas where the temperature has the potential to drop below freezing. The heater is adjusted to 15˚C. To change the setting, rotate the temperature control knob on the heater to a new temperature setting.
  • Page 29: Single Phase Wiring Diagram

    (SEE NOTE 1) DIRECTION INTERCHANGE (NOTE 4) FUSE (YE) PURPLE & GRAY WIRES INTERNAL MOTOR 3.2A ON MODEL SL585 WIRING (BL) (TB 2) OR THE RED & GREEN WIRES 1 - BLUE ON MODEL SL595 2 - WHITE 3 - ORANGE...
  • Page 30: Single Phase Schematic

    S I N G L E P H A S E S C H E M A T I C W W A A R R N N I I N N G G To protect against fire and electrocution: •...
  • Page 31: Three Phase Wiring Diagram

    T H R E E P H A S E W I R I N G D I A G R A M ON/OFF 230V CONNECTION SWITCH (SEE NOTE 3) OVERLOAD (BK) (BK) (GY) (SL595 GN) 230V (BK) BRAKE (PU) (SL595 RD) SOLENOID 3 PHASE (BK)
  • Page 32: Three Phase Schematic

    T H R E E P H A S E S C H E M A T I C W W A R N I N G To protect against fire and electrocution: BLACK (SL595 ORANGE) • DISCONNECT power BEFORE installing or servicing operator. AUXILIARY RELAY •...
  • Page 33: Repair Parts

    Gear reducer (30:1) key and conduit. 39-34786 Clutch disk K75-10177 Brake hub kit K20-1050C-2P Motor - models SL585-50-11, Complete with: Brake hub, set screw, SL585-50-21, SL585-50-81 push on fastener and feather key. K20-3050C-4P Motor - models SL585-50-23, SL585-50-43, SL585-50-83 K75-34828...
  • Page 34: Illustrated Parts - Model Sl585

    I L L U S T R A T E D P A R T S - M O D E L S L 5 8 5 SL585 ILLUSTRATED PARTS K5 ( K75-34842) K7 (K75-34791) K6 ( K75-34790) K8 (K29-32410)
  • Page 35: Repair Parts - Model Sl595

    R E P A I R P A R T S - M O D E L S L 5 9 5 INDIVIDUAL PARTS SERVICE KITS ITEM PART # DESCRIPTION ITEM PART # DESCRIPTION K20-1050C-2P Motor - models SL595-50-11, 71-B120G Brake kit - 115 Volt models SL595-50-21, SL595-50-81 71-B208G...
  • Page 36: Illustrated Parts - Model Sl595

    I L L U S T R A T E D P A R T S - M O D E L S L 5 9 5 SL595 ILLUSTRATED PARTS K7 (K75-18493) K1 (71-B120G) (71-B208G) (71-B240G) (71-B575G) K3 (K75-12858) K2 (K75-18618) K6 (K29-32410) K4 (K75-18620) 312HM Receiver Mounted to...
  • Page 37: Electrical Box

    SERVICE KITS K1C3196-3 Antenna VARIABLE PARTS ITEM PART # DESCRIPTION 25-2006 Overload - 6 AMP - SL585-50-21, SL585-50-81, SL595-50-21, & K72-34818 Limit shaft kit (SL585 only) SL595-50-81 Complete with: Limit shaft, limit 25-2008 Overload - 8 AMP - SL585-100-21, nuts, limit bearings, limit sprocket, shim washers, compression ring, SL585-100-81, SL595-100-21, &...
  • Page 38: Safety Accessories For Secondary Entrapment Protection

    S A F E T Y A C C E S S O R I E S F O R S E C O N D A R Y E N T R A P M E N T P R O T E C T I O N The following devices are acceptable for Safety Accessories for secondary entrapment protection.
  • Page 39: Notes

    N O T E S...
  • Page 40: Warranty Policy And Service

    W A R R A N T Y P O L I C Y A N D S E R V I C E ® LIFTMASTER TWO YEAR LIMITED WARRANTY The Chamberlain Group, Inc. warrants to the final purchaser of this product, for the structure in which this product is originally installed, that it is free from defect in materials and/or workmanship for a period of two years from the date of purchase.