Chamberlain ELITE SL585UL Installation Manual

Ac slide gate operator
Hide thumbs Also See for ELITE SL585UL:
Table of Contents

Advertisement

Quick Links

AC SLIDE GATE OPERATOR
SL585101UL
1 HP, 120/208-240 Vac Single Phase
SL585103UL
1 HP, 208-240/480 Vac Three Phase
SL585105UL
1 HP, 575 Vac Three Phase
SL585151UL
1-1/2 HP, 120/208-240 Vac Single Phase
SL585501UL
1/2 HP, 120/208-240 Vac Single Phase
SL585503UL
1/2 HP, 208-240/480 Vac Three Phase
SL585505UL
1/2 HP, 575 Vac Three Phase
• THIS PRODUCT IS TO BE INSTALLED AND
SERVICED BY A TRAINED GATE SYSTEMS
TECHNICIAN ONLY.
• This model is for use on vehicular passage gates
ONLY and not intended for use on pedestrian
passage gates.
• This model is intended for use in Class I, II, III and
IV vehicular slide gate applications.
• Visit LiftMaster.com to locate a professional
installing dealer in your area.
• This gate operator is compatible with MyQ
Security+ 2.0
LiftMaster
300 Windsor Drive
Oak Brook, IL 60523
ELITE SERIES INDUSTRIAL
INSTALLATION MANUAL
accessories.
®
Access installation and technical support
guides or register this product
and
®
SL585ULTECH
Take a photo of the
1.
camera icon including
the points ( ).
Send it in by texting the
2.
photo to 71403.

Advertisement

Table of Contents
loading

Summary of Contents for Chamberlain ELITE SL585UL

  • Page 1 ELITE SERIES INDUSTRIAL AC SLIDE GATE OPERATOR INSTALLATION MANUAL SL585101UL 1 HP, 120/208-240 Vac Single Phase SL585103UL 1 HP, 208-240/480 Vac Three Phase SL585105UL 1 HP, 575 Vac Three Phase SL585151UL 1-1/2 HP, 120/208-240 Vac Single Phase SL585501UL 1/2 HP, 120/208-240 Vac Single Phase SL585503UL 1/2 HP, 208-240/480 Vac Three Phase SL585505UL...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS SAFETY Photoelectric Sensors and Edge Sensors ..........29 Locks ....................29 Safety Symbol and Signal Word Review ..........2 Usage Class ...................3 EXPANSION BOARD OVERVIEW UL325 Entrapment Protection Requirements ........3 EXIT FAIL Switch .................30 Safety Installation Information ...............4 AC FAIL Switch ..................30 Gate Construction Information ...............5 ANTI TAIL Switch .................30 INTRODUCTION...
  • Page 3: Usage Class

    SAFETY Usage Class Class I - Residential Vehicular Gate Operator A vehicular gate operator (or system) intended for use in garages or parking areas associated with a residence of one-to four single families. Class II - Commercial/General Access Vehicular Gate A vehicular gate operator (or system) intended for use in a commercial location or building such as a multi-family housing unit (five or more single family units), hotel, garages, retail store, or other buildings...
  • Page 4: Safety Installation Information

    SAFETY Safety Installation Information 1. Vehicular gate systems provide convenience and security. Gate systems 9. The Stop and/or Reset (if provided separately) must be located in the are comprised of many component parts. The gate operator is only one line-of-sight of the gate. Activation of the reset control shall not cause component.
  • Page 5: Gate Construction Information

    SAFETY Gate Construction Information Vehicular gates should be installed in accordance with ASTM F2200: Standard Specification for Automated Vehicular Gate Construction. For a copy, contact ASTM directly at 610-832-9585 or www.astm.org. General Requirements Vehicular Horizontal Slide Gates Gates shall be constructed in accordance with the provisions The following provisions shall apply to Class I, Class II and Class III given for the appropriate gate type listed, refer to ASTM F2200 vehicular horizontal slide gates:...
  • Page 6: Introduction

    INTRODUCTION Carton Inventory NOT SHOWN: Documentation Packet, Chain #50 - 25 feet, Eye Bolt Kit Tools Needed 3/4" wrench for 1/2" concrete anchors, Screwdrivers (Phillips head and flat head), Cable cutters and strippers...
  • Page 7: Operator Specifications

    INTRODUCTION Operator Specifications Usage Classification Class I, II, III, & IV Accessory Power Main Control Board: 24 Vdc, 500 mA max. Terminal Strip: 24 Vac, 2.2 A max. for 120/208-240 Vac, Single Phase and 208-240/480 Vac, Three Phase 24 Vac, 1.3 A max. for 575 Vac, Three Phase Maximum Gate Weight 1/2 HP (1 Phase and 3 Phase): 1000 lbs.
  • Page 8 INTRODUCTION Main AC Supply Phase Full Load Amps Single 120 Vac 11.2 Amps (17.2 Amps including Accessory Outlets) 208-240 Vac 5.6 Amps Three 208-240 Vac 3.1 Amps 480 Vac 1.8 Amps 575 Vac 1.4 Amps Single 120 Vac 16 Amps (22 Amps including Accessory Outlets) 208-240 Vac 8 Amps Three...
  • Page 9: Site Preparation

    INTRODUCTION Site Preparation Check the national and local building codes BEFORE installation. Conduit and Concrete Pad Safety Trench and install conduit. Before trenching, contact underground utility Entrapment protection devices are required to protect against any locating companies. Conduit must be UL approved for low and high entrapment or safety conditions encountered in your gate voltage.
  • Page 10: Installation

    INSTALLATION To AVOID damaging gas, power or other underground utility lines, To prevent damage to the operator or gate, DO NOT drive the limit contact underground utility locating companies BEFORE digging more (nuts) actuators on the shaft past their normal positions. than 18 inches (46 cm) deep.
  • Page 11: Step 1 Install The Operator

    INSTALLATION Step 1 Install the Operator Check the national and local building codes before installation. Pad mount installation Retro-fit installation The operator is shipped from the factory with the lower mounting angles configured out (Figure 1). If you have pad constrictions, either angle can be unbolted and reversed to angle in.
  • Page 12 INSTALLATION Post mount installation Retro-fit installation The operators come from the factory configured to mount to an inside the frame post mount dimension of 26" (66 cm) (outside to outside of posts). The frame comes slotted to accommodate posts 24-1/8" (61 cm) to 26"...
  • Page 13: Step 2 Attach The Chain

    INSTALLATION Step 2 Attach the Chain DO NOT run the operator until instructed. 1. Mount gate brackets to the vertical front and rear posts of the gate. 2. Remove the operator cover. 3. Locate and engage the manual release handle and lock it in place. 4.
  • Page 14: Step 3 Install Entrapment Protection

    INSTALLATION To prevent SERIOUS INJURY or DEATH from a moving gate: ALL gate operator systems REQUIRE two independent entrapment Locate entrapment protection devices to protect in BOTH the open and protection systems for each entrapment zone. close gate cycles. Entrapment protection devices MUST be installed to protect anyone Locate entrapment protection devices to protect between moving gate who may come near a moving gate.
  • Page 15 INSTALLATION Wire Entrapment Protection Devices There are three options for wiring the entrapment protection devices depending on the specific device and how the device will function. Refer to the specific entrapment protection device manual for more information. These entrapment protection device inputs are for monitored devices, which include pulsed photoelectric sensors, resistive edge sensors, and pulsed edge sensors.
  • Page 16: Step 4 Earth Ground Rod

    INSTALLATION Step 4 Earth Ground Rod Use the proper earth ground rod for your local area. The ground wire must be a single, whole piece of wire. Never splice two wires for the ground wire. If you should cut the ground wire too short, break it, or destroy its integrity, replace it with a single wire length.
  • Page 17 INSTALLATION Single Phase The operator is field configurable for usage at 120, 208, and 240 Vac. Factory default is 120 Vac. For 208 Vac Operation Unplug the motor harness from the “120V” receptacle on the power board and plug the harness in to the “208V / 240V” receptacle.
  • Page 18 INSTALLATION Three Phase The operator is field configurable for usage at 208, 240, and 480 Vac. Factory default is 240 Vac. For three phase 575V operators, the operator is configured at the factory for 575V ONLY. For 208 Vac Operation Ensure the motor harness is plugged in to the “208V / 240V”...
  • Page 19: Step 6 Dual Gate Setup

    INSTALLATION Step 6 Dual Gate Setup There are two options for dual gate communication: wired or wireless. Follow the directions according to your application. Do not use wired and wireless communication simultaneously. Wireless setup To activate the wireless feature: 1. Choose an operator to be the network primary operator. All wireless accessories will need to be programmed to the primary operator. NOTE: We recommend that all accessories and board configurations are set on the primary operator.
  • Page 20 INSTALLATION DUAL GATE WIRE TYPE (SHIELDED TWISTED PAIR CABLE) Wired setup 22AWG up to 200 feet (61 m) 18AWG - 200-1000 feet (61-305 m) Before digging, contact local underground utility locating companies. Use Wire must be rated at 30 Volt minimum PVC conduit to prevent damage to cables. 1.
  • Page 21: Adjustment

    ADJUSTMENT Adjust the Handing and Limits To reduce the risk of SEVERE INJURY or DEATH: Without a properly installed safety reversal system, persons NEVER use force adjustments to compensate for a binding or sticking (particularly small children) could be SERIOUSLY INJURED or gate.
  • Page 22: Adjust The Clutch

    ADJUSTMENT Readjust the Limits To readjust the limits, follow the “Set the Limits” and “Set the Force and Run Distance” instructions above. It is important that the force and run distance are set after every limit readjustment. Adjust the Clutch The friction clutch system is not an automatic obstruction sensing device.
  • Page 23: Obstruction Test

    ADJUSTMENT Fine Tune the Force Once the initial limits have been set, the REVERSAL FORCE DIAL on the control board is used for fine tuning the force where wind or environmental changes may affect the gate travel. The REVERSAL FORCE DIAL is set to minimum at the factory. Based on the length and weight of the gate it may be necessary to make additional force adjustments.
  • Page 24: Operator Overview

    OPERATOR OVERVIEW...
  • Page 25: Control Board Overview

    CONTROL BOARD OVERVIEW...
  • Page 26: Learn Button

    CONTROL BOARD OVERVIEW Learn Button The LEARN button is used for programming (refer to Programming). Diagnostic Display The diagnostic display will show the operator type, firmware version, and codes. The operator type will display as “SL” followed by a “58” which indicates the operator type as SL585UL. The firmware version will show after the operator type, example “1.2”. For more information about the codes refer to the Troubleshooting section.
  • Page 27: Reversal Force Dial

    CONTROL BOARD OVERVIEW Reversal Force Dial The REVERSAL FORCE dial adjusts the force. See the Adjustment section. Settings 1-3: Fixed force settings (the force will not adjust due to gate wear or temperature changes) Settings 4-10: Automatically increase the force due to gate wear or temperature changes Test Buttons Used to operate the gate (OPEN, STOP and CLOSE).
  • Page 28: Wire Accessories To Control Board

    WIRE ACCESSORIES TO CONTROL BOARD All control wiring used to connect external devices to Class 2 circuits of the operator must be (QPTZ) Power-Limited Circuit Cables, Type CL2, CL2P, CL2R, or CL2X or other cable with equivalent or better electrical, mechanical, and flammability ratings. Three Button Control Station TERMINALS FUNCTION...
  • Page 29: Photoelectric Sensors And Edge Sensors

    WIRE ACCESSORIES TO CONTROL BOARD Photoelectric Sensors and Edge Sensors The EYES/EDGE terminals are used for connecting entrapment protection devices. At least two external monitored entrapment protection devices are required prior to gate movement; one in the open and one in the closed direction. Monitored entrapment protection devices should have been installed with the operator at the time of installation.
  • Page 30: Expansion Board Overview

    EXPANSION BOARD OVERVIEW To AVOID damaging the circuit board, relays or accessories, DO NOT connect more than 42 Vdc (32 Vac) to the AUX relay contact terminal blocks. EXIT FAIL Switch OPEN: If the EXIT plug-in loop detector (model LOOPDETLM) detects a fault, then the gate will open and remain open until fault is cleared. CLOSE: If the EXIT plug-in loop detector (model LOOPDETLM) detects a fault, faults are ignored (EXIT loop is faulted and inoperative).
  • Page 31: Auxiliary Relay 1 And 2

    EXPANSION BOARD OVERVIEW Auxiliary Relay 1 and 2 Normally Open (N.O.) and Normally Closed (N.C.) relay contacts to control external devices, for connection of Class 2, low voltage (42 Vdc [34 Vac] max 5 Amps) power sources only. Function of relay contact activation determined by switch settings. SWITCH SETTINGS AUX RELAY AUX RELAY 1...
  • Page 32: Wire Accessories To Expansion Board

    WIRE ACCESSORIES TO EXPANSION BOARD Photoelectric Sensors and Edge Sensors The EYES/EDGE terminals are used for connecting entrapment protection devices. At least two external monitored entrapment protection devices are required prior to gate movement; one in the open and one in the closed direction. Monitored entrapment protection devices should have been installed with the operator at the time of installation.
  • Page 33: Loops

    WIRE ACCESSORIES TO EXPANSION BOARD Loops TERMINALS FUNCTION WIRING EXAMPLE EXIT Loop wire connection for plug-in loop detector when loop is inside secured area near gate. Open command - opens a closed gate Soft open (maintained switch does not override external safeties and does not reset alarm condition) If maintained, pauses Timer-to-Close at OPEN limit Opens a closing gate and holds open an open gate...
  • Page 34: Field Wiring

    ADDITIONAL WIRING To protect against fire and electrocution: For continued protection against fire: DISCONNECT power (AC or solar and battery) BEFORE installing or Replace ONLY with fuse of same type and rating. servicing operator. Field Wiring...
  • Page 35: Programming

    PROGRAMMING Remote Controls (Not Provided) ® A total of 50 Security+ 2.0 remote controls or KPW250 keypads and 2 keyless entries (1 PIN for each keyless entry) can be programmed to the operator. When programming a third keyless entry to the operator, the first keyless entry will be erased to allow the third keyless entry to be programmed.
  • Page 36: Liftmaster Internet Gateway (Not Provided)

    PROGRAMMING LiftMaster Internet Gateway (Not Provided) To program the operator to the LiftMaster Internet Gateway: Program using the learn button on the operator's control board: Program using the reset button on the operator: 1. Connect the ethernet cable to the LiftMaster Internet Gateway and the 1.
  • Page 37: Settings

    SETTINGS Gate operator setup examples The following are example setups for the gate operator. Your specific site requirements may be different. Always setup the operator system to the site requirements, including all necessary entrapment protection devices. RESIDENTIAL: One to four residential homes sharing a gated entrance/exit, allowing vehicle access trumps security concerns COMMERCIAL/GENERAL ACCESS: A residential community (more than four homes) having one or more gated entrances/exits, allowing vehicle access trumps security concerns COMMERCIAL: Business site where security (gate closed) is important...
  • Page 38: Dual Gate Settings

    SETTINGS Dual Gate Settings NOTE: We recommend that all accessories and board configurations are set on the primary operator. Main Control Board FEATURE PRIMARY OPERATOR SECONDARY OPERATOR Timer-to-Close Set the TTC dial to desired setting Bi-Part Delay Switch Bi-Part Delay: ON (will open last and close first) Bi-Part Delay: OFF (will open first and close last) Tandem Mode: OFF Tandem Mode: OFF...
  • Page 39: Maintenance

    MAINTENANCE IMPORTANT SAFETY INSTRUCTIONS To reduce the risk of SEVERE INJURY or DEATH: READ AND FOLLOW ALL INSTRUCTIONS. Test the gate operator monthly. The gate MUST reverse on contact with an object or reverse when an object activates the noncontact ANY maintenance to the operator or in the area near the operator sensors.
  • Page 40: Troubleshooting

    TROUBLESHOOTING To protect against fire and electrocution: For continued protection against fire: DISCONNECT power (AC or solar and battery) BEFORE installing or Replace ONLY with fuse of same type and rating. servicing operator. Diagnostic Codes To View the Codes The codes will show on the diagnostic display. The operator will show the code sequence number followed by the code number: To Exit...
  • Page 41: Diagnostic Codes Table

    TROUBLESHOOTING Diagnostic Codes Table Some codes are saved in the code history and some are not. If a code is not saved it will briefly appear on the display as it occurs, then disappear. External Entrapment Inherent Entrapment LiftMaster System Installed System Informational Protection...
  • Page 42 TROUBLESHOOTING Code Meaning Solution Saved CLOSE EYE/INTERRUPT triggered, causing reversal, preventing close, or resetting TTC CLOSE EDGE triggered, causing reversal, NO IF an obstruction occurred, no action required. If an obstruction did NOT preventing close, or canceling TTC occur, check alignment, inputs, and wiring on main control board OPEN EYE/EDGE triggered, causing reversal or preventing opening CLOSE EYE/INTERRUPT triggered, causing...
  • Page 43: Operator Alarm

    TROUBLESHOOTING Operator Alarm If a contact sensor detects an obstruction twice consecutively the alarm will sound (up to 5 minutes) and the operator will need to be reset. When the inherent force of the operator (RPM/current sensor) detects the following (twice consecutively) the alarm will sound (up to 5 minutes) and the operator will need to be reset.
  • Page 44: Troubleshooting Chart

    TROUBLESHOOTING Troubleshooting Chart SYMPTOM POSSIBLE CAUSES SOLUTIONS Operator does not a. No power to control board a. Check AC power run and diagnostic b. Open fuse b. Check fuses display not on. c. Defective control board c. Replace defective control board Control board a.
  • Page 45 TROUBLESHOOTING SYMPTOM POSSIBLE CAUSES SOLUTIONS Shadow loop does a. Vehicle detector setup incorrectly a. Review Shadow loop detector settings. Adjust settings as needed. not keep gate at b. Defective vehicle loop detector b. Replace defective Shadow loop detector. open limit. Obstruction in a.
  • Page 46: Accessories

    ACCESSORIES ® ® Universal remote controls Security+ 2.0 learning remote LiftMaster internet gateway LiftMaster Cloud™ connected controls access protocol - high capacity Models 811LM and 813LM Model 828LM Models 892LT and 894LT Model CAPXL Plug-in loop detector LiftMaster door and gate monitor 3-button control station Stop Button Model LOOPDETLM...
  • Page 47: Repair Parts

    REPAIR PARTS REPAIR PARTS (NOT SHOWN) ELECTRICAL BOX REPAIR PARTS (NOT SHOWN) Heater Kit, 480V HTR460 Power Board Horse Power ID, 3 Phase 1/2 HP K94-38062-1 Feather Key K80-9001 Power Board Horse Power ID, 3 Phase 1 HP K94-38062-2 Chain Guard Kit Complete with: Chain guard, chain Power Board Horse Power ID, 575V 1/2 HP K94-38062-4 K75-34824...
  • Page 48: Warranty

    This limited warranty gives you specific legal rights, and you may also have other rights which vary from state to state. 300 Windsor Drive Oak Brook, IL 60523 LiftMaster.com © 2018, The Chamberlain Group, Inc. - All Rights Reserved 01-39377B...

Table of Contents