Using the Monitor Panel

5.1 Using the LCD Screen

The LCD screen at the top of the Monitor Panel provides an operator interface with the
UPS. Figure 5-2 identifies the display fields discussed in the following sections.
System Normal
A
Alarm:
Notice: None
B
C
Meters
D
System
Load Amps
E
Meters

Figure 5-2. Parts of the LCD Screen (Typical for Powerware 9315 300 480/480V UPS)

A
The UPS status area contains three lines that display the current state of the UPS. The first line
shows the present operational mode of the UPS. The second line shows the highest level of the
current active alarms, and the third line shows any notices the UPS has posted. (For more
information about alarms and notices, see Chapter 10, "Responding to System Events.")
B
The battery charge box shows the percentage of battery capacity available.
C
The menu box shows the currently selected menu and lists the options available on that menu. The
title at the top of the menu box is also shown below on the menu bar (E). Press the
buttons to scroll up and down through the options in the menu box.
D
The currently selected option is highlighted in the menu box. Press the
the highlight up or down. The data in the information area (G) changes accordingly.
E
The menu bar lists the titles of the menus. The title of the menu currently displayed in the menu
box is highlighted. When you press the
data in the menu box and the information area change accordingly.
F
The timestamp shows the current date and time. This date and time are recorded in the Event Log
when a notice or alarm is activated.
G
The information area contains data about UPS status and operations. Select a menu option to
display statistics or graphics.
5-2
Uninterruptible Power System
None
Battery
Percent
100%
VAB
480
IA
480
KVA
399
VAB
480
Events Statistics Graphics Setup
EATON Powerware
9315 UPS (200–300 kVA) Operation Manual S 164201036 Rev F powerware.com
®
Input
VBC
VCA
FREQ
VAB
480
480
60.0
480
IB
IC
IA
480
480
361
KW
PF
0.95
379
Bypass
VBC
VCA
480
480
and
buttons to move the highlight left or right, the
04 MAY 1997
14:23:45
Output
VBC
VCA
FREQ
480
480
60.0
IB
IC
IN
361
361
000
KVA
KW
PF
300
240
0.80
Battery
V
I
540
000
and
and
buttons to move
F