IBM x3455 - System - 7984 User Manual page 77

User manual
Hide thumbs Also See for x3455 - System - 7984:
Table of Contents

Advertisement

Boot block recovery
jumper (J51)
NMI switch (SW1)
Power-on password
jumper (J52)
Force power-on
jumper (J37)
BMC update
jumper (J34)
Wake on LAN
bypass jumper (J48)
Attention:
Before you change any switch settings or move any jumpers, turn off
the server; then, disconnect all power cords and external cables. See the safety
information that begins on page v. Do not change settings or move jumpers on any
system-board switch or jumper blocks that are not shown in this document.
To change the position of the power-on password jumper, complete the following
steps.
1. Review the safety information that begins on page v.
2. Turn off the server and peripheral devices and disconnect all power cords and
external cables; then, remove the cover (see "Removing the cover" on page 23).
3. Move the jumper on J52 from pins 1 and 2 (the default) to pins 2 and 3 to
bypass the power-on password check.
4. Replace the cover, connect the server to a monitor, and then connect it to a
power source.
5. Turn on the server and wait until POST is completed.
6. Turn off the server and disconnect all power cords and external cables; then,
remove the cover.
7. Move the jumper on J52 from pins 2 and 3 to pins 1 and 2.
8. Replace the cover, connect the server to a USB keyboard, monitor, USB mouse,
and peripheral devices; then, connect the server to a power source.
BMC reset
jumper (J36)
Chapter 3. Configuring the server
63

Advertisement

Table of Contents
loading

This manual is also suitable for:

798431uSystem x3455 type 7984System x3455 type 7986

Table of Contents