Serverguide Problems - IBM 88728AU - System x3950 - 8872 Datacenter High Availability Installation Manual

Installation guide
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Symptom
A serial device does not work.

ServerGuide problems

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Symptom
The ServerGuide Setup and
Installation CD will not start.
The SCSI RAID program cannot
view all installed drives, or the
operating system cannot be
installed.
The operating-system
installation program
continuously loops.
The ServerGuide program will
not start the operating-system
CD.
The operating system cannot be
installed; the option is not
available.
72
IBM System x3950 Type 8872 and System x3950 E Type 8874: Installation Guide
Action
1. Make sure that:
v The device is compatible with the server.
v The serial port is enabled and is assigned a unique address.
v The device is connected to the correct port.
2. Reseat the following components:
a. Failing serial device
b. Serial cable
c. Remote Supervisor Adapter II SlimLine (if one is present)
d. I/O board
3. Replace the components listed in step 2 one at a time, in the order shown,
restarting the server each time.
Action
v Make sure that the server supports the ServerGuide program and has a
startable (bootable) CD (or DVD) drive.
v If the startup (boot) sequence settings have been altered, make sure that the CD
drive is first in the startup sequence.
v If more than one CD drive is installed, make sure that only one drive is set as
the primary drive. Start the CD from the primary drive.
v Make sure that there are no duplicate SCSI IDs or IRQ assignments.
v Make sure that the hard disk drive is connected correctly.
Make more space available on the hard disk.
Make sure that the operating-system CD is supported by the ServerGuide program.
See the ServerGuide Setup and Installation CD label for a list of operating-system
versions that support the ServerGuide program.
Make sure that the operating system is supported on the server. If the operating
system is supported, either there is no logical drive defined (SCSI RAID systems)
or the ServerGuide System Partition is not present. Run the ServerGuide program
and make sure that setup is complete.

Advertisement

Table of Contents
loading

This manual is also suitable for:

X3950 8872X3950 e 8874

Table of Contents