Vstatic Load Test-Ver 0.90 - Biostar M7 VIF Test Report

Engineering validation test report
Hide thumbs Also See for M7 VIF:
Table of Contents

Advertisement

M/B
VID Setting
Electronic Loading
O.C.P test
Over 60A Pass/Fail
Vcore
Vcore
Loading
Voltage
0A
1.723
30A
1.724
32A
1.720
34A
1.716
36A
1.712
38A
1.708
40A
1.704
42A
1.701
44A
1.696
46A
1.692
Comments:
68
V
STATIC LOAD TEST-Ver 0.90
CORE
Test Environment
VIF/0.90
1.75V
Chroma 63030
PWM
5V ATX
Input
Connector
12.03
5.10
12.26
4.91
12.28
4.90
12.29
4.88
12.31
4.86
12.33
4.84
12.34
4.81
12.34
4.77
12.33
4.71
12.30
4.63
Power Supply
PWM
Engineer Signature
Pass
O.V.P test 2.07V
AGP Slot
PCI Slot
1.5V
5V
3.3V
1.508 5.09
3.36
1.508 4.91
3.30
1.508 4.89
3.29
1.508 4.87
3.29
1.508 4.86
3.28
1.508 4.84
3.28
1.508 4.81
3.27
1.508 4.76
3.23
1.508 4.70
3.19
1.508 4.62
3.13
ST-300BLV
Hip 6004dcb
K.E.Y.
Pass/Fail
Temperature
MOS(℃)
5V
5.09
37.9
4.88
74.0
4.86
80.1
4.85
84.2
4.83
92.7
4.81
100.7
4.77
105.2
4.72
111.8
4.66
117.1
4.58
126.2
Pass
Board(℃)
37.0.
68.6
73.5
79.1
86.0
95.0
98.5
104.8
111.5
119.1

Advertisement

Table of Contents
loading

Table of Contents