12. Set the replacement power supply distribution module into the chassis and slide it backward
against the power supply. See letters "A" and "B" in the figure below.
13. Push down on the lever at the front of the power distribution the power supply distribution
module while lining up the holes on power supply stands on chassis. See letter "C" Press down
until power supply sits firmly in place.
14. Connect the main power, CPU power, and power signal from the power supply to the server
board. Refer back to Figure 64 and see your server board documentation to locate the
connection points for these cables.
15. Install the air baffle. For instructions on installing the baffle and you have hot-swap drives
installed, see
"Installing the Large Hot-swap Air Baffle (Backplane
on installing the baffle if you are using fixed drives, see
(No Backplane
16. (Hot-swap system only): Connect the 2x3 power cable to the backplane. Refer back to Figure
65 for a diagram of this connection point.
17. (Fixed drive system only): Connect the 2x3 power cable to the SATA power adapter cable
Refer back to Figure 66 to see how these cables connect.
18. (Hot-swap system only): Connect the flex cable to the server. Refer back to Figure 63 and see
your server board documentation to locate the connection points for this cable.
19. Install the hot-swap power supply/supplies. For instructions, see
Supply."
20. Install the PCI riser assembly. For instructions, see
76
A
* Air baffle not shown for illustrative purposes.
Figure 68. Installing the Power Distribution Module
Installed)."
B
TP01353
Installed)." For instructions
"Installing the Fixed Drive Air Baffle
"Installing a Hot-swap Power
"Installing the PCI Riser
C
Assembly."