Error Code/Symptom
11XX
(System board
serial port 1 or 2 error)
0001200
(Machine check
architecture error)
2
1301
(I
C cable to
front panel not found)
2
1302
(I
C cable
from system board to power on
and reset switches not found)
2
1303
(I
C cable
from system board to power
backplane not found)
2
1304
(I
C cable to
diagnostic LED board not found)
(The Service
1600
Processor is not functioning)
Do the following before
replacing a FRU:
1.
Ensure that a jumper is not
installed on J45.
2.
Remove the ac power to the
system, wait 20 seconds;
then, re-connect the ac
power. Wait 30 seconds;
then, power-on the system.
1601
(The system is
able to communicate to the
Service Processor, but the Service
Processor failed to respond at the
start of POST.)
Do the
following before replacing a
FRU:
1.
Remove the ac power to the
system, wait 20 seconds;
then, re-connect the ac
power. Wait 30 seconds;
then, power-on the system.
2.
Flash update the Service
Processor.
FRU/Action
1.
Disconnect external cable on serial port.
2.
Run Configuration/Setup
3.
System Board
1.
Processor 1
2.
Optional Processor 2
1.
Cable
2.
Front Panel
3.
Power Switch Assembly
4.
System Board
1.
Cable
2.
Power Switch Assembly
3.
System Board
1.
Cable
2.
Power Backplane
3.
System Board
1.
Power Switch Assembly
2.
System Board
1.
System Board
1.
System Board
125