6-6. Setting the split number

Pattern 1
Pattern 2
Pattern 3
4964Q
2nd step
The setting for memory switch No. 403 lets you select the split mode.
[Continuous split]
Memory switch No. 403 = 0 (Split mode is enabled after split data is detected)
Memory switch No. 403 = 1 (Split mode is always enabled)
• Sewing is carried out each time in the order of steps 1 → 2 → 3 → 1 (for example, if there are two sections of split
data).
[Independent split]
Memory switch No. 403 = 2
• The pattern for the displayed split number is sewn independently.
6. USING THE OPERATION PANEL (ADVANCED OPERATIONS)
If split data (data that causes sewing to pause) exists within a single program,
the numbers that are used to specify the patterns that are separated by split
data are called split numbers.
Pattern 1: Split No. 1
Pattern 2: Split No. 2
Pattern 3: Split No. 3
1. Press the
for a program that contains split data.
• The program number will flash in the PROGRAM No.
2. Depress the foot switch to the 2nd step.
(If using a two-pedal foot switch, lower the work clamp
before depressing the start switch.)
• The feed mechanism will move to the home position
• The program number will stop flashing and illuminate
3. Press the SELECT key (3) so that the SPLIT No.
indicator (4) illuminates.
• The split number will appear in the menu display (5).
4. Press the
4965Q
BAS-300G, BAS-311G, BAS-326G
or
key (1) to select a program number
display (2).
and the program number will be accepted.
steadily.
or
key (6) to set the split number.