Table 1-2. LCD Status Messages
Code
N/A
E1000
E1118
E1211
16
Information Update
Text
SYSTEM NAME
FAILSAFE, Call
Support
CPU Temp
Interface
ROMB Batt
Causes
A 62-character
string that can be
defined by the user
in the System Setup
program.
The SYSTEM NAME
is displayed under
the following
conditions:
• The system is
powered on.
• The power is off
and active errors
are displayed.
Check the system
event log for critical
failure events.
The BMC is unable
to determine
the CPU(s)
temperature status.
Consequently, the
BMC increases
the CPU fan speed
to maximum
as a precautionary
measure.
RAID battery is
either missing, bad,
or unable to
recharge due to
thermal issues.
Corrective Actions
This message is for
information only.
You can change the
system ID and
name in the System
Setup program. See
"Using the System
Setup Program" in
the Hardware
Owner's Manual.
See "Getting Help"
in the Hardware
Owner's Manual.
Turn off power to
the system and
restart the system.
If the problem
persists, see
"Getting Help"
in the Hardware
Owner's Manual.
Reseat the RAID
battery connector.
See the "RAID
Battery" and see
"Troubleshooting
System Cooling
Problems" in the
Hardware Owner's
Manual.