Dell PowerEdge 1950 Information Update page 12

Information update
Hide thumbs Also See for PowerEdge 1950:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Table 1-1. System Messages (continued)
Message
PCI BIOS failed to
install
PCIe Degraded Link
Width Error:
Embedded device
Expected Link Width
is n
Actual Link Width
is n
PCIe Degraded Link
Width Error:
Integrated device
Expected Link Width
is n
Actual Link Width
is n
PCIe Degraded Link
Width Error: Slot n
Expected Link Width
is n
Actual Link Width
is n
PCIe Training
Error: Embedded
device
12
Information Update
Causes
PCIe device BIOS (Option
ROM) checksum failure
detected during shadowing.
Cables to expansion card(s)
loose; faulty or improperly
installed expansion card(s).
Faulty system board or riser
board.
The specified PCIe device
is faulty or improperly
installed.
Faulty or improperly
installed PCIe card in
the specified slot.
Faulty system board
or riser board.
Corrective Actions
Reseat the expansion
card(s). Ensure that all
appropriate cables are
securely connected to the
expansion card(s). If the
problem persists, see
"Troubleshooting System
Expansion Cards" in the
Hardware Owner's Manual.
See "Getting Help" in the
Hardware Owner's Manual.
For a SAS controller
daughter card, reseat the
card in the dedicated PCIe
connector. See "Installing a
SAS Controller Daughter
Card" in the Hardware
Owner's Manual. If the
problem persists, see
"Getting Help" in the
Hardware Owner's Manual.
Reseat the PCIe card in the
specified slot number. See
"Expansion Cards" in the
Hardware Owner's Manual.
If the problem persists,
see "Getting Help" in the
Hardware Owner's Manual.
See "Getting Help" in the
Hardware Owner's Manual.

Advertisement

Table of Contents
loading

Table of Contents