Dell PowerEdge 1950 Information Update page 13

Information update
Hide thumbs Also See for PowerEdge 1950:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Table 1-1. System Messages (continued)
Message
PCIe Training
Error: Integrated
device
PCIe Training
Error: Slot n
Remote Access
Controller cable
error or incorrect
card in the RAC
slot.
NOTE:
All TPM information messages appear after the BMC option ROM has been
loaded during POST.
TPM configuration
operation honored.
TPM Failure
Causes
The specified PCIe device
is faulty or improperly
installed.
Faulty or improperly
installed PCIe card in the
specified slot.
RAC cables not connected,
or RAC card installed in
wrong expansion slot.
System now resets.
A Trusted Platform Module
(TPM) function has failed.
Corrective Actions
For a SAS controller
daughter card, reseat the
card in the dedicated PCIe
connector. See "Installing
a SAS Controller Daughter
Card" in the Hardware
Owner's Manual. If the
problem persists, see
"Getting Help" in the
Hardware Owner's Manual.
Reseat the PCIe card in the
specified slot number. See
"Expansion Cards" in the
Hardware Owner's Manual.
If the problem persists, see
"Getting Help" in the
Hardware Owner's Manual.
Check that the RAC cables
are connected, and that the
RAC card is installed in the
correct expansion slot. See
"Installing a RAC Card" in
the Hardware Owner's
Manual.
Information only.
See "Getting Help" in the
Hardware Owner's Manual.